“dixie verse gy TECH TIPS Dixie Part Numbers: A-766 A-778 A-788 A-792 A-795 A-796 A-1697 A-1698 A-1700 A-1701 A-1702 A-1704 A-6498 A-7001 A-7002 A-7007 S-8814 S-80234 TS-1758 TS-1767 101-24101 101-24104 101-24107 101-24201 160-55110 201-29103 201-38101 246-30115 Applications: 2005 — 2006 Thomas Built Buses Condition: The operator of the vehicle may complain of one or more of the following conditions: – the vehicle fails to start – the vehicle has caught on fire – the battery is run down/dead Cause: A potential cause for the above conditions is the main battery cable chaffing on a bracket next to the starter resulting in a short circuit to ground. Correction: When working on a vehicle form the above applications inspect the main battery cable. Replace and re-route the battery cable if applicable. REV: 20100701 Courtesy of RecallCast TSB_702.doc Dixie Tech Tips are intended for use by professional technicians, and are not for the general public. They are written to inform technicians of conditions that may exist or as a guide to aid in diagnosing and servicing a vehicle. All references to original equipment manufactures, vehicle manufactures and any other Trade Mark names are for the sole purpose of identifying the vehicle and or part that the Tech Tip applies to. This document is property of Dixie Electric Ltd. and is not to be copied or distributed with out written permission.