HEXIE TECH TIPS Dixie Part Numbers: A-1920 A-1921 A-1922 101-50212 101-50213 3501-5025 3501-5026 Applications: Transit/Coach applications with an alternator from the list below installed. A-1920 A-1921 A-1922 101-50212 101-50213 Condition: The regulator requires replacing but did not work directly out of the box. Cause: A possible cause for the above condition is that the alternator can be either A circuit (the regulator controls the ground circuit) or B circuit (the regulator controls the power circuit). Correction: The above regulators only function with B circuit alternators (connection shown below). connector strap location Should the vehicle being worked on have an alternator that is an A circuit alternator, there will be a large strap connecting the B+ to the F1 terminals, the following steps must be performed: – Remove the strap that connected terminals B+ and F1. – Move the field wire from terminal F2 to terminal F1. Torque the nut to 60-70 Ib in. – Install a ground strap from terminal F2 to ground via the end frame bolt as shown above. Torque the end frame bolt to 56-85 lb in. The remote sense is optional but the manufacturer recommends using remote sense anytime the battery cable is more then 10 feet in length. Attached are three typical wiring configurations to assist, should any trouble shooting be required. REV: 20100812 Courtesy of The Dixie Technical Department TSB_167.doc Dixie Tech Tips are intended for use by professional technicians, and are not for the general public. They are written to inform technicians of conditions that may exist or as a guide to aid in diagnosing and servicing a vehicle. All references to original equipment manufactures, vehicle manufactures and any other Trade Mark names are for the sole purpose of identifying the vehicle and or part that the Tech Tip applies to. This document is property of Dixie Electric Ltd. and is not to be copied or distributed with out written permission.