Basic alternator theory: Charging system Part Il Reprinted with permission from the Prestolite Electric, Inc. manual “Basic Alternator Theory” published in 1989. The alternator basic AC generator system is essentially the same as the DC generator system. However, the armature and field are reversed in position. In the DC generator, the conductor is moving and the magnetic field is stationary. In the AC generator or alternator, the magnetic field is rotated and the conductor is stationary. The operation is the same. The magnetic field is rotated, its flux lines cut the conductor and induce a voltage in it (Figure 18). + D.C. FIELD EXCITATION 360° Figure 18—A rotating field around a stationary conductor produces an AC voltage to the load. Note one advantage already—the load or output connections are stationary- fixed terminals, while in the DC generator, the load is connected to the power source via brushes riding on the commutator. This output current can be in the order of 30 to 160 amps, depending on the unit. The alternator field current is passed through brushes. The field current is in Y (WYE) RO TOS ROTOR WINDING WINDING “ DC EXCITING DC EXCITING & FIELD FIELD = STATOR|WINDING— Figure 19-Diagram of Delta & Y stator connections. DELTA STATOR —–—–Y STATOR STATOR WINDING ~AC = AC the order of 2 to 3 amps. The brush current in the alternator is less than 1/10 the brush current in the DC generator. The brushes contact smooth slip rings and not an inter- rupted commutator as in a DC generator. A practical alternator consists of many more conductor loops than shown. These loops are in the form of coils. Three coils are used. Each coil can be considered a separate AC generator. By mechanically positioning the three coils 120 degrees apart, three AC output voltages 120 degrees out of phase are induced. A diode bridge is used to rectify the AC voltages. Figure 19 shows two types of stator connections commonly used in alterna- tors: the “Y” (Wye) connection and the Delta connection. Either may be used, the choice is dependent on many design consid- erations, both in performance and circuit requirements. The graph in Figure 20 compares the output obtained from a typical alternator with the same stator connected first as a “Y” and then a delta circuit. The exciting field is rotating and induc- ing a voltage in each of the phase wind- ings. These voltages are 120 degrees apart in phase. (Note: These are electrical degrees as shown on the sinewave graph and not mechanical degrees of shaft rota- tion.) Figure 20-Typical alternator output curves. 1000 2000 3000 4000 5000 6000 7000 8000 9000 ALTERNATOR SHAFT R.P.M. The output voltages from the three phase alternator are shown in Figure 21— this voltage is rectified by six silicon diode rectifiers. Rectification converts the nega- tive (bottom) portion of the waveform and results in a positive DC output. 120°) 120° 120° + 0 0° 180° 360° Figure 21-Output voltage from three-phase alternator. A comparison of the electrical charac- teristics of the DC generator and the AC generator (alternator) is shown in Figure 22. A comparison of the alternator stator and the generator armature in which the output current is produced as shown in Figure 23. The mass and balance of the generator armature is critical since it is rotating. Therefore, it is simpler and more reliable to produce a stationary armature winding such as used in the alternator for this reason. The generator armature windings are soldered to the commutator sections. If excessive heat and/or excessive speeds are developed, the solder can actually be thrown from these connections. Figure 22—Comparison of DC and AC generator characteristics. The alternator stator output is connected to the load via stationary connectors—the armature is connected to the load via brushes on the commutator which is a make-break circuit with attendant arcing. The rotor winding is wound concentric to the shaft and will not shift due to cen- trifugal force of its rotation. In the DC generator, the field is station- ary. In the AC generator, the rotor (field) spins within the stator windings. The generator field compared to the
File Type:
pdf
File Size:
5 MB
Categories:
eren