Making generator field coils COLUMN BY WES GRUENINGER SR. AND BOB THOMAS H ave you ever found yourself in need of a set of generator field coils that are no longer available? There are manufacturers out there that will still custom -make a brand new set for you. It is not a low price solution, but it is always available if the customer is willing to pay. There is another choice you may never have thought of—make a set yourself! coils. The Ace and IPM field coil catalogs are available for download on the ERA website if you do not already have them. You will find a full list of field coil resources at the end of this article. The set of field coils shown in Figure 1 is from a Delco 036J three-brush genera- tor, the original unit from a 1936 Buick. The pole shoe size did not match any- thing in either the Ace or the IPM catalog. As you can see in the photo, they are badly burned, even though the rest of the generator is in very good condition. At the end of this article we will explain the most likely reason why the coils ended up Figure 1—Burned generator field coils. like this and the best way to prevent it from happening again. First, we will go step- by-step through the process of winding a new set of coils by hand. Start by sketching a dia- gram showing the position of the CW and CCW coils (Fig- ure 2). Lay them out with the curved inside surfaces facing We should note here that it is best to exhaust all resources before deciding to make your own set of coils. To search for replacement coils, first measure the length and the width of the pole shoes. Then, look for a similar set in either the Ace or IPM field coil catalogs. While neither company is no longer in business, their part numbers are alive and well and can be cross referenced easily to Wilson or Dixie part numbers. Both Wilson and Dixie still manufacture generator field up. Also note which coil leads Terminal 7 Delco generator 936J 6-volt 19 gauge wire, 150 tus per col Pole shoe 2.3” L – 1.6” W – .34”H Figure 2—Hand-drawn sketch. are joined together and where each of the other leads go. In this case, one lead goes to the third brush, and the other lead goes to a field terminal. One thing you need to know is the exact wire gauge size. It is very important that you measure the copper only, without any insulation. In this case, it was easy, because the insulating enamel was already burned away. Removal of the insulation by burning is better than by trying to scrape it off, because you need all of the copper to get an accurate measurement. Scraping might remove some of the cop- per. A torch will do this job quickly. Measure the thickness of the bare wire in several different places to be absolutely sure that you get the right gauge size (Figure 3). Use a wire gauge chart to determine the AWG size of the wire. Such a chart is available in the online ERA Technical Library, or you can find one on the Internet by searching on “wire gauge chart.” Be sure to write it down. You must document everything that you can about the set of coils you want to make. Figure 8 has been included for you to use as a worksheet. Figure 3—Measuring the wire O.D. After you have a good diagram, and you know the wire gauge size, you must count the number of turns in one of the coils. The coils will be the same, so there is no need to count them both. To make this job a little easier, separate the two coils where they are spliced together. Remove any wrapping material left on the coils. Do not be tempted to completely unwind the coils as you count. It makes a big mess of loose wire, and it is impossi- ble to start over if you lose count. Hold the unwrapped coil in your hand as shown in Figure 4 and slowly pull each turn away as you count it. Write the num- ber of turns on your diagram. (Our sub- ject coil had exactly 150 turns.) Figure 4—Counting the coils. You will also need to estimate how much wire you will need. Measure one of the outer turns with a ruler. It is important that you measure an outer turn because the inner turns require slightly less wire. Multiply the length of one turn by the total number of turns, and you will have a rough estimate of the length of magnet wire you will need to make each coil. You would rather have too much wire than not enough, so err on the high side. Magnet

File Type: pdf
File Size: 5 MB
Categories: eren