ELECTRICAL REBUILDER’S ASSOCIATION—Technical Document $S201402C New Bosch Starter With soft-engagement solenoid BY NATHAN UNGER Figure 1—O 001 267 025 Bosch starter his is an ordinary looking, 24v 5.5kW planetary gear reduction Bosch starter with a very ordinary looking solenoid that is activated by an auxiliary relay. The Bosch number is 0 001 261 025, and the Lester number is 19802. It was used on Scania DC9 engines—this one is from a Metro track jaw crusher (see Figures 2 and 3). It has, however, a special way of accomplishing “soft engagement.” You need to know this so that you don’t accidentally burn out the 0.1 ohm resistor-wire-wound pull-in coil inside the solenoid, when you are measuring the solenoid pull-in coil current. To begin with, I will discuss my observations about what the scope showed as I was activating this starter (see Figure 4). Notice the different current levels in that fraction of a second, just when the starter is first activated. I had the current clamp around the ground cable so that it would show solenoid and motor-current behaviors together. The first plateau (let’s call it time zone 1) represents about 200 amps, then there is a short dip (time zone 2), in which the current goes down to about 16 amps. Then it shoots way up before it starts sloping down again. What’s happening here, is that the current flows into the “S” terminal through a special pair of normally-closed contacts, then through a series resistor, which also serves as the pull-in coil. The current then flows on through the starter motor to ground. The resistor reduces the amount of current that the motor sees during the soft-engagement interval (time zone 1). The resistor is engaged for only about 1/30th of a second—not enough time to heat up, and not enough time to give the starter drive anything but a slight spin—maybe 1 or 2 revolutions. This spin is in addition to the twist that happens as the drive travels forward on the spiral splines. This extra spin helps to reduce the chance of tooth abutment and the possible resultant gear grinding when full power is applied. To recap .. On the scope screen- capture, we see the short duration of 200 amps through the armature as it “flicks” the drive (time zone 1). Next, we see the solenoid hold-in coil current by itself (about 16 amps) just in that instant when the contact disc is moving between the bottom contacts and the main contacts (time zone 2). Finally, we see the motor start-up current. The start-up current has an almost vertical slope up as the BOSCH STARTER WITH AUXILIARY RELAY 0 001 261 025 24 VOLTS 5.5kW 12 TEETH CLOCKWISE 92mm FLANGE CAN USE SOLENOID # 2 339 402 362 Figure 2—O 001 267 025 Bosch starter specifications www.electricalrebuilders.org SOLENOID NOTE: BATTERY(S) STARTER, SOLENOID = i / AND AUXILIARY RELAY OQ © ARE ALL INTERNALLY GROUNDED. 0 TO START SWITCH THE STARTER IS THEN © O GROUNDED TO THE ENGINE BLOCK. O STARTER Figure 3—Diagram of starter with auxiliary relay. An ERA Publication. ©2014, Electrical Rebuilder’s Association. All rights reserved. No portion of the guide may be reproduced in any way, or stored in any electronic retrieval system without the prior written consent of the Electrical Rebuilder’s Association. Page 1

File Type: pdf
File Size: 4 MB
Categories: eren