ELECTRICAL REBUILDER’S ASSOCIATION—Technical Document SS201410A www.electricalrebuilders.org Denso F-Series 4kW Starter BY BOB THOMAS AND WES GRUENINGER, SR. he straight drive 4kW Denso F-Series diesel starter was introduced in the late 1970s as a direct replacement for the aging Delco 35MT (see Figure 1). This starter has been giving some rebuilders headaches ever since, by staying engaged on the vehicle following engine start, even though it operates properly on a bench test. This series starter was used on various Caterpillar, Onan, Hino, Mercruiser and most prominently John Deere applications with 10 different Lester numbers covering this design in 12 volts. One of the peculiarities of this starter is a soft-engagement feature that is achieved by rotating the armature at reduced speed during solenoid pull-in. This helps to eliminate the possibility of the pinion milling the flywheel when abutment occurs. However, this feature has also contributed toward making the rebuilding of this starter more of a challenge. Most starters accomplish a smooth engagement by grounding the solenoid’s pull-in coil through the motor terminal. During pull-in, current that is limited by the solenoid’s pull-in coil flows through the motor to create a very slow rotation of the armature and pinion during pull- in. While this works well for gas engine applications, flywheel milling has long been a consequence when the initial forces required to turn a diesel engine enter the picture. The Denso F-Series starter grounds its pull-in coil through the motor terminal as well, but it also utilizes a two- pole shunt coil wound within the four- pole series-parallel field coils to rotate the armature during pull-in. This motor shunt coil is energized directly from the switch terminal of the solenoid and rotates the armature with significantly greater force than can be achieved in the conventional circuit previously described. You can easily identify this starter by the external shunt power wire that runs from the solenoid’s switch terminal to the shunt-coil terminal on the side of the field case (see Figure 2). The F-Series starter’s shunt coil is in parallel with the solenoid’s coils. It should not be confused with Denso IIF-Series starters that later replaced the F-Series. While they look very similar, and both utilize shunt coils in the field case connected with a jumper wire to the solenoid, the difference is where that lead connects. In the case of the IIF solenoid, the jumper connects to the ground side of the pull-in coil (see Figure 3), not the switch terminal. The IIF motor shunt coil is in series with the solenoid’s pull-in coil. That solenoid operates and can be tested in a conventional manner. To explain, a starter shunt is simply a parallel circuit with the armature, unlike the series-circuit field coils we see in most cranking motors. Many starter manufacturers have utilized shunt coils to limit armature speed and reduce Figure 1—This Denso 4kW F-Series starter, part number 028000-3290, has a unique solenoid circuit that can cause a peculiar problem. Figure 2—Note that the small wire lead from the solenoid to the field case connects to the switch terminal on the Denso F-Series solenoid. An ERA Publication. ©2014, Electrical Rebuilder’s Association. All rights reserved. No portion of the guide may be reproduced Page 1 in any way, or stored in any electronic retrieval system without the prior written consent of the Electrical Rebuilder’s Association.
File Type:
pdf
File Size:
8 MB
Categories:
eren