Technical Document SS-0901A v2.0 Produced by the Electrical Rebuilder’s Association www.electricalrebuilders.org Nikko’s Solenoid-Control Relay Circuit That small relay you’ll find attached to many Nikko industrial starters is more than just your ordinary starter relay. Nikko calls it a solenoid- control relay. As the name implies, it controls the operation of the starter solenoid. Nikko utilizes the output from the alternator R_ terminal, in conjunction with this relay, to prevent accidental engagement of the starter once the engine is running. This document will explain how the system works and how to test the relay to ensure it is working properly. Figure 1 — Nikko Solenoid-Control Relay Photo courtesy Electric Motor Service (EMS) The Nikko solenoid-control relay is used on many different applications, including Komatsu, Hitachi, John Deere, Link-Belt and other industrial equipment. In nearly all applications, it is mounted directly on the starter. If you look closely, you’ll notice there’s an electronic component attached to what looks like a standard 4-terminal relay. For purposes of explaining how the relay works, we’ll call the electronic part the controller and the 4- terminal relay the relay. The diagram in Figure 2 shows the relay’s internal circuits. The controller has five wires coming out of the potting compound on the underside. Two wires are soldered to connections on the relay which go to the internal relay coil. The ground wire is black, and in most cases, it’s attached to the relay’s bracket. Another wire, black/white on most applications, is connected to the harness leading back to the start side of the ignition switch. The fifth wire, white/green on most applications, is connected to the harness leading to the alternator’s R terminal. This wire is used to sense when the engine is running. Electronic Controller Figure 2 – Internal Parts of Control Relay There are two things you need to know about the Nikko alternator used with the control relay. First, it is self-excited by a resistor connected internally between B+ and the diode trio. Second, the R terminal is also connected to the trio. The R terminal serves as a secondary output to signal the controller that the alternator is running. The diagram in Figure 3 is for the Hitachi EX200 excavator, but all equipment using a Nikko system with control relay will be similar. The battery relay shown in Figure 3 prevents small drains from discharging the batteries whenever the equipment sits idle for long periods of time. This is important, because the alternator’s excitation resistor will present a small parasitic drain. When the switch is turned on, the battery relay closes to connect the batteries to: the starter solenoid, the alternator, the control relay and the rest of the electrical system. At this point, the R terminal will have no (or very low) voltage present, because the field circuit will bleed-off nearly all current coming through the alternator’s internal excitation resistor. Since the engine has not yet started, the trio cannot provide output. When the switch is turned to the Created by Wes Grueninger and Bob Thomas for the Electrical Rebuilders Association – © 2009, Electrical Rebuilder’s Association — All rights reserved. No portion of this guide may be reproduced in any way, or stored in any electronic retrieval system without the prior 1 written consent of the Electrical Rebuilder’s Association Technical Document SS-0901A v2.0 Produced by the Electrical Rebuilder’s Association www.electricalrebuilders.org start position, the black/white wire signals the controller to start. With no (or very low) voltage present on the white/green wire, the controller allows the current from the switch to pass through to energize the relay, which in turn activates the starter solenoid. Once the engine starts and the alternator excites, the R terminal becomes a secondary output Batteries (24V ) – + – OO0000 12V Electronic Controller Alternator terminal. The controller immediately senses that the alternator is charging, and it cuts the activation current to the relay. As long as the engine is running and system voltage is present at the R terminal, the control relay cannot be activated to re-engage the starter. Ignition Switch + OO0000 BLACK / WHITE HITACHI EX200 Excavator (other Nikko systems using a Control Relay are similar) Figure 3- Typical Wiring Diagram Created by Wes Grueninger and Bob Thomas for the Electrical Rebuilders Association – © 2009, Electrical Rebuilder’s Association — All rights reserved. No portion of this guide may be reproduced in any way, or stored in any electronic retrieval system without the prior 2 written consent of the Electrical Rebuilder’s Association Technical Document SS-0901A v2.0 Produced by the Electrical Rebuilder’s Association www.electricalrebuilders.org Figure 4 – Photos of a Nikko starter, alternator and relay. Photo courtesy Electric Motor Service (EMS) Testing the system for no-crank 1. With the ignitio