ERA Office: Monday – Friday 9:00-5:00 CST

275 W. BROWN ST, UNION, MO 63084

636-584-7400

office@electricalrebuilders.org

ERA Tech Helpline: 636-584-TECH (8324)

Instructions 2822C FAIRBANKS-MORSE TYPES FM. FM-H, FMO&FM-OH MAGNETOS General Improper functioning of the magneto is often be- lieved to be the cause of much engine trouble or start— ing difficulty arising from other sources. To prevent unnecessary and inadvisable adjustment of the magneto an arbitrary “service chart” has been prepared (Fig. 3) and it is recommended that the procedure suggested be carefully followed in the order shown. Investigation of engine trouble by this method results in simpler and more thorough service. Testing the Magneto Spark Remove all of the cable terminals from the magneto end cap sockets to eliminate the possibility of engine firing. Insert one end of a short piece of wire in one of the sockets and hold the other end about 1/8 inch from magneto frame. Turn the engine over slowly sever-— al times and watch closely for a spark between the wire and the frame. If a spark is observed, the testing arrangement should be moved to the next terminal and the procedure repeated. If a spark occurs at each terminal, it is very unlikely that the magneto is the source of the engine difficulty. TROUBLE POSSIBLE CAUSE ID. Spark Plug Corroded, worn or damaged points; eracked or carbonized insulators. KH. Magneto Brushes, points, impulse coupling. Instructions No. 2822C August 1, 1944 Field Service and Adjustment Information A. Flooding Hot or cold engine; over-rich fuel | Dry out cylinders: crank engine slowly, fuel shut off; or mixture. let engine stand idie for short interval. B. Insufficient] Empty fuel tank; clogged fuel sup-| Replenish fuel; clean fuel supply system and check carbu— Fuel or Air | ply lines; clogged air intake. retor; clean air intake system. C. Ignition Loose or corroded terminals; broken] Clean or replace cable terminals; inspect solderedor clamp- Connections | cables; short circuited switch. ed joints, test and replace cables; check ignition switch. New plugs; clean points and insulators; adjust point gap to recommended opening: never attempt to adjust center electrode. See instructions beginning Paragraph #2. Type FM-OH6A Magneto – Dismantling When no spark is obtained from one or more of the magneto terminals, the distributor end cap should be taken off by removing the four end cap screws. The following details should then be checked: (a) Inspect the carbon brushes. These brushes should move freely in their holders and should have a slight spring pressure; replace brushes which are worn or irregular. (b) Clean the distributor dise with a clean cloth and carbon tetrachloride. Do not use sandpaper. Service of Breaker Points Carefully examine the breaker contact points for indications of pitting or pyramiding. (a) If necessary, the contact points should be made smooth with a small tungsten file or fine stone. The entire breaker mechanism may be easily removed from the magneto for point resurfacing, eliminating the possibility of dropping filings in the magneto housing. Points must be adjusted after resurfacing. (b) Points which cannot be reconditioned satis-— factorily should be replaced by a complete new set. SUGGESTED REMEDY Page One Page 2 2822C FAIRBANKS-MORSE TYPES FM, FM-H,FMO &FM-OH MAGNETOS Adjustment of Breaker Points The breaker point gap should measure .020 inch when fully open. To adjust the point gap the two locking screws (Fig. 4) of the stationary point bracket should be loosened, after which the eccentric head adjusting screw can be turned until the proper position has been obtained. The locking screws should be tightened before final measurement of the breaker point gap is made. DISTRIBUTOR GEAR CAM FELT WICK BREAKER POINTS CONDEN’ STATIONARY CONTACT. eee SUPPORT BRACKET LOCKING SCREWS ECCENTRIC HEAD ADJUSTING SCREW BREAKER ARM TERMINAL SCREW Fig. 4 -— Breaker Plate Assembly Lubrication of Magneto Careful design and special factory preparation eliminates the necessity of field lubrication. Ball bearings are packed with the finest grade of high melting point grease (FMCO3); the porous Oilite type sleeve bearings are mounted in bearing supports which provide reservoirs containing additional supplies of a particu— larly suitable grease (FMCO4). Lubricants are to be renewed only during a complete overhaul of the magneto by an Authorized Service Station. Reassembly, Sealing & Testing To reseal the magneto according tofactory standards all gasket surfaces should be thoroughly cleaned and a new gasket provided. A thin coat of the special FMCO Gasket Sealing Varnish should be applied to the face of the distributor end cap and the gasket fixed in place. Mount the distributor end cap on the magneto frame and tighten the screws securely. Test the magneto agein as outlined in Paragraph 2 and,.if no spark oc— curs, remove and send the magneto to an Authorized Service Station. Magneto to Engine Timing If the magneto has been removed from the engine, replacement necessitates accurate retiming. Two meth- ods are described below: (A) the advance spark position method and (

File Type: pdf
File Size: 6 MB
Categories: magnetos