ERA Office: Monday – Friday 9:00-5:00 CST

275 W. BROWN ST, UNION, MO 63084

636-584-7400

office@electricalrebuilders.org

ERA Tech Helpline: 636-584-TECH (8324)

SERVICE INSTRUCTIONS AND PARTS LIST “Li BATTERY DISTRIBUTOR MODELS WIcO The Prestolite Company Division of ELTRA Corporation TOLEDO, OHIO Form $-523W revised February 1962 Printed in U.S.A… LP BATTERY DISTRIBUTOR SYSTEMS The system is designed to produce high voltage surges which are directed to the spark plugs. The sparks are timed to appear at the plug at the right moment. DISTRIBUTOR FUNCTION The distributor opens and closes the low tension circuit between the battery and the coil by means of breaker points so that the primary winding is supplied with intermittent surges of current. Each surge builds up a magnetic field in the coil. The breaker cam opens the points making the magnetic field collapse causing the coil to produce a high voltage surge. The distributor times the surges according to engine specifications. The distributor sends the high voltage surge through the rotor, cap and high tension wire to the plug that is ready to fire. A top view and cross section of the Wico distributor indicating the major parts is shown in figures 1] and 3. An exploded view of the parts is shown in figure 6. HOW IT WORKS The primary circuit is opened and closed by the breaker mechanism (breaker arm and fixed contact plate) and the breaker cam. The cam is rotated by the dis- tributor shaft in conjunction with the centrifugal advance parts. The shaft is driven by a coupling or gear within the engine usually by the engine camshaft. The shaft and breaker cam are rotated at 12 engine speed and the breaker cam has the same number of lobes as there are cylinders. (There are some exceptions to this rule.) As the cam opens the points a high voltage surge is pro- duced. For example on a four cylinder, four cycle engine one complete revolution of the distributor fires all four cylinders. Thus, with every two crankshaft revolutions or every complete breaker cam revolution, each cylinder will fire once. The condenser is connected across the contact points to produce a quick collapse of the coil field so that a high voltage will occur. The condenser prevents the points from arcing. After the surge is produced in the coil it is conducted through the high tension lead to the center terminal of the cap. It then continues down to the rotor and to the outer terminal in the cap under which the distributor rotor contact is positioned at the time the Page 2 surge occurs. The plug that is ready to fire is connected to this outside terminal by a high tension lead. Thus, a system for distributing high voltage surges to the correct spark plug is produced by means of the cap, rotor and high tension leads. SPARK ADVANCE Timing of the spark with relation to piston position has to vary in order to obtain best engine performance. The spark must occur at the plug earlier in the com- pression stroke at high speed to allow the fuel-air mixture adequate time to ignite and burn, giving power to the piston as it starts down on the power stroke. Under throttled operation a smaller amount of fuel-air mixture goes into the cylinder and is less highly compressed. Because of this, advancing the spark will allow fuller use of the fuel-air mixture introduced. CENTRIFUGAL ADVANCE UNIT Wico distributors have a centrifugal advance which moves the cam in advance of the distributor shaft by means of centrifugal weights which moves the cam ahead of the distributor shaft. The unit is made up of a breaker cam, an advance weight group, a stop weight group, advance and stop weight springs, and a drive shaft group. Figure 6 shows these parts in an exploded view and Figure 2 shows the parts assembled. The weights are made so that one end of the weight works freely in an outward and inward motion. The other end of the weight, which appears to be a hook, fits in the slot located at the bottom of the breaker cam. As the speed is increased the weights through centrifugal force move outward causing the hooked end of the weight to exert force against the side of the slot in the breaker cam moving it to an advanced position as shown in Figure 5. The springs in the advance unit are primarily necessary to produce a specific type of advance curve and to return the weights to a ‘‘no advance”’ position as shown in Figure 4, In the Wico type advance, springs having various characteristics are employed to produce advance curves for different applications. Such surves are more or less special or tailored to individual engine requirements. wicto SERVICE INSTRUCTIONS DISTRIBUTOR CAP & ROTOR After removal of the distributor cap, wipe with clean cloth and check for tracking or cracks. Check the carbon brush and spring for wear and free movement in the dis- tributor cap. If the carbon is worn and needs to be re- placed, it is recommended that the group consisting of the carbon and spring be used. Inspect the rotor for cracks and carbonized paths which would allow leakage .to ground. Such a defect would mean replacement was necessary. DUST SEAL & CAM WIPER FELT Examine the dust seal and r

File Type: pdf
File Size: 7 MB
Categories: magnetos