eneral Instruction Manual. September 1994 ACE ELECTRIC Columbus, Kansas MODEL E-2122 ALTERNATOR ANALYZER This manual should be read completley before attempting to operate the tester. I. SPECIFICATIONS A. Physical Size 9 3/4 deep X 11 3/8 wide X 4 3/8 high Weight 9 pounds B. Electrical 115 VAC, 4 amp 60 Hz. Single phase II. CONTROLS AND INDICATORS A. Front Panel 1. Amp meter 3 1/2 digit that shows the amount of current for the test being performed. Readings will repeat within 1/10 amp. 2. Power switch When in the “on” position, the amp meter should display. | 3. Circuit breaker This is located on the back panel. Excessive testing or overloading the tester will cause this to open turning off the tester. 4. Function Switch The test function must be selected before the test leads are used for any test. 5. Diode lights These lights are used in two tests. a. Will determine negative or positive diodes in the “Diode Test. b. Will aid in finding a defective diode in a partial aliternator assembly in the “Final Testâ„¢. 6. Test lead socket This 6 pin receptacle is polarized. Two pins are spaced differently from the other 4 pins. DO NOT FORCE THE PLUG INTO THE SOCKET. A. Test Lead Assembly The 6 prong plug attaches to the front panel. (OBSERVE PLUG POLARITY.) The red and black probes are used to apply the test power to the item being tested. The clip leads are used only for the Final Test function. Leads should not be left touching each other, or touching a common metal surface, when the unit is turned on. enna a et CAUTI ONS 1. Do not spill any liquids in or on the tester. Do not allow any test leads to touch each other while the unit is turned on. Leads touching each other will cause excessive heating in the tester and may reduce life of the tester. Each stator test should be limited to 5 seconds. Allow at least 10 seconds between tests. Continuous testing will cause the unit to overheat and reduce the life of the tester. Turn off the power switch when not in use. OPERATING INSTRUCTIONS A. ROTOR TEST NOTE: 2. Iii. This tester is designed to test the actual rotor current. Arcing may occur while making probe contact. Touch the probes to the slip ring area but not in the path where the brushes make contact. 1. Turn the test select switch to the rotor position. 2. Place the black test probe to one slip ring. 3. Place the red test probe to the other slip ring. 4. Read the amperage. If the meter reads higher than anticipated, the coil a. Sia b. is possibly shorted. If there is no display of amperage, the coil is open, or there is a poor connection to either slip ring. Rotors that look alike may have different designed amperage draw. This test may be used for sorting these different field coils. Amperage ranges, for the field coil is to be determined by other specifications. 5. Check for shorting from coil to shaft. Touch one probe to the rotor shaft. b. Touch the other probe to each slip ring. No amperage should be observed. a. Cc. NOTE (This tester will not check for extreme low current shorts from the coil winding to the shaft.) An Ohm meter. or a hi-pot tester should be used if more critical testing is required. B. STATOR TEST 1. Turn the test select switch to the Stator position. 2. Disconnect all stator wires or terminals. 3. Measure the current of all three phases NOTE. – aa. Measurement is taken from the three stator leads that connect to the diodes. The common connection of a “Y” connected stator is not used as a terminal in this test. This common “y” terminal will usually have three wires at its junction. ab. “y” connected stators may vary. Some common “y” – connections connect to a fourth set of diodes. This connection will have three wires and is not normally used in this test. ac. Some stators may have 6 leads to the connection points. Each lead (or winding) may even have two wires (double wound). These are to be tested differently than other stators. See step 6. a. Mentally mark the three leads as 1, 2, and 3. b. Touch the black probe to lead #1 and touch the red probe to lead #2 & #3. Amperage readings should be within 3 amps. c. Touch the black probe to lead #2 and the red probe to lead #3. Amperage reading should be within 3 amps of step b. 4. Test for shorts to lamination stack. a. Touch one probe to a stator terminal and the other to a clear metal point of the lamination stack. No amperage reading should be observed. Sorting stators of varied amperage ratings may be accomplished if standard amperage readings are established by the operator for each type of stator. Stator readings may vary slightly from one tester to another due to component tolerances in the tester. NOTE: – Amperage readings from a tester, of this generic type, will not determine the amperage output of the stator. Wire size, turns in each slot, type of termination and air gap to the rotor are only some of the variables of alternator output relative to the stator. 6. Testing stators with 6 leads NOTE: – The beginning and ending of each coil has a lead protruding. a. Touch the black probe to one lead and touch the red probe to another lead which produces amperage. b. Touch the black probe to one of the other 4 leads and touch the red probe to another lead that produces amperage.

File Type: pdf
File Size: 5 MB
Categories: manuals