OPERATION MANUAL ean OT-0018 FREE-RUN STARTER TESTER Lexan INTERNATIONAL PRODUCTS & MANUFACTURING, INC. CHECK LIST OPERATION MANUAL IPM OT-0018 FREE-RUN STARTER TESTER (with Mounting Base) IPM WARRANTY | | AyLuytsi tt ‘ j OPERATION MANUAL enn OT-0018 FREE-RUN STARTER TESTER penn OT-0018 OPERATION INSTRUCTIONS GENERAL DESCRIPTION THE IPM OT-0018 Free Run Starter Tester will test all domestic and foreign starters for cars and light trucks. It’s easy to use: Hook up the two cables, push the operate switch and observe the voltage and amperage readings. The test takes less than 10 seconds. For maximum conservation of energy, the OT-0018 draws current only when the operate switch is depressed, Below the switch is a pilot jight that glows when the DC power supply is on. The tester requires no battery. A 20-amp fuse protects the DC power supply so that improper cable hook-up will not damage the tester. OPERATION PLUG THE POWER CORD into a three-lead grounded receptacle wired for 110 volts AC. Mount the starter to be tested on the V-block, making sure the open area of the starter drive end is in the special protective cage. Tighten the screw clamp to prevent starter movement during the test. ON A STARTER WITH A SOLENOID, connect the small red jumper to the solenoid post (normally marked “‘S”’). Be sure the starter drive moves all the way forward in the drive housing as the solenoid is engaged. ON A STARTER WITH NO SOLENOID, clamp the black cable to the starter housing or the V-block (Figure 1). Clamp the red cable to the field post or the lead coming Terminal Strip (on Transformer) Caution: Unplug the AC power card before touching the Terminal Strip. Do not move transformer wires from Terminal Strip. OT-0018 comes factory-set with wire No. 5 connected to Terminal 2. This accommodates average variations in AC line voltage. To raise DC voltage that is low due to low AC line voltage, move wire No.5 from Terminal 2 to Terminal 1. To tower DC voitage that is high due to high AC line voltage, move wire No. 5 from Terminal 2 to Terminal 3. Do not move wires connected to Terminal 4 in any case. 321 REMOVE. out of the starter housing. CAUTION: When the smal! red jumper lead is not being used, attach the clip end to the positive (red) clamp (Figure 2), This will prevent a direct short which could blow a fuse or damage the meter or the DC power supply. Once proper hook-up has been made, press the operate switch (located on the left side of the front panel). As soon as the meters have stabilized (within 10 seconds) take the voltage and amperage readings. CAUTION: Do not exceed 10 seconds per test. If during the course of any test the ammeter deflects full scale and remains there, stop the test to prevent current over- load. CHECKING THE OT-0018 THE TESTER SHOULD BE plugged into a live 110-volt AC circuit. Push the operate switch. The red pilot light should light and the voltmeter should read approximately 12 volts without a starter hook-up. In case of difficulty, refer to the trouble-shooting chart on the opposite page. CAUTION: Do not short the power cables. Never press the operate switch while both cables are hooked together or touching the base plate or otherwise making electrical contact. This could result in a DC power supply failure not covered by the warranty. ‘oo OT-0018 WIRING DIAGRAM Omer, fh He +LEAD AMMETER —LEAO | [olf VOLTMETER 4 lead No5 7 Ly FIGURE 1 Pecan OT-0018 HOOK-UPS 1. Mount starter securely on V-block, being sure starter drive is in protective cage. 2. Connect positive (red) cable to correct starter post as shown below. If small jumper lead is not FIGURE 2 shorting. 3. Connect negative (black) cable to V-block or starter housing as shown in Figure 1. CHRYSLER GENERAL MOTORS FORD Lenin OT-0018 TROUBLE-SHOOTING CHART INPUT LINE VOLTAGE AC INPUT ___» FUSE <= SUAEGES «oS ADJUSTMENT TERMINAL TRANSFORMER ___________, RECTIFIER BANK OY SHUNT AAG FEAD AMMETER TRANSIENT PILOT VOLTMETER if there is no reading during a test, Check forja blown. SUPPRESSOR LIGHT fa fuse (located on the front panel)-With 4,good 20-amp fuse installed, proceed by testing a starter. If the tester still does not function properly, at probably has. =] defective DC power supply AS 0 CI AW DC LEAD ben OT-0018 EXPLODED VIEW Case Rectifier Assembly, Positive = 162 OT-1167 Transient Suppressor ¥ OT-5074 ; 6 d Insulator OT-1195 i ~ Insulator OT-1195 OT-1179 Power Cord Rectifier Assembly, Negative onne ") a OT-1166 = Voltmeter Wiring Harness t—<—= — (Not Shown) OT-1174 Transformer Assembly OT-1168 Power Switch Front Panel OT-1172 OT-1161 Fuse Holder Assembly OT-1054 Pilot Light Assembly -11 Fuse, 20A OFS Locking Screw Base Plate OF1186 OPs OT-1163 a - Retainer — —=S ~ OT-1194 @ _ Mounting Feet SS aol Locking Plate OT-1009 : < OT-1164 Starter Mounting Base OT-1177 Red Cable with Clamp OT-1170 Red Jumper with Clip Black Cable with Clamp OT-1171 OT-1169