ERA Office: Monday – Friday 9:00-5:00 CST

275 W. BROWN ST, UNION, MO 63084

636-584-7400

office@electricalrebuilders.org

ERA Tech Helpline: 636-584-TECH (8324)

RICHARD & BARBARA VENSEL (815) 459-0355 (800) 662-6099 3710 RIVERSIDE DRIVE CRYSTAL LAKE, ILLINOIS 60014 USA FAX (815) 459-0442 VENSEL AUTO ELECTRIC ENTERPRISES EQUIPMENT SUPPLIER ¢ Tests for shorts, grounds, poor connections, and bad contacts on Delco, Chrysler, etc. solenoids. ¢ Left meter indicates current draw for both ‘‘pull-in’’ and ‘“‘hold-in’’ coils. e Right meter indicates solenoid contact condition. * Both meters are large (41/2”) and easy to read. * Also checks ‘‘R”’ terminal operation on Delco solenoids. e ‘‘Production-line’’ rugged. Built-in circuit breaker protects against overloads. e¢ Built in power supply. No extra converter or battery required. ¢ Dimensions 15%” wide x 202” deep x 91/2” high. 24 Ibs. ¢ 115 V.A.C. 8 Amps. 60 Hz. e Full one year guarantee. Model SL1i2 12 Volt Model SL-12/24 12 & 24 Volt Y Solenoid Tester Model SL-24 VENSEL OPERATING INSTRUCTIONS This Tester will check any 12 or 24 volt automotive solenoid including foreign and heavy-duiy Tester will operate only from a 110-130 volt (A.C.), 50-60 Hertz, 3-prong (grounded) outlet. Solenoid Types… FORD TYPE solenoids have a single electro-magnetic coil connected between the small (“switch”) terminal post and — ground (solenoid frame). When this coil is energized with (2 volt D.C. power, the coil actuates a plunger which drives a copper disk into contact with the two large copper terminal posts of the solenoid. This action connects the car battery to the starter causing the engine to crank. The Ford type solenoid may also have a secondary or “Auxiliary Contact” connected to a second small terminal post. The purpose of this “auxiliary ” coract is to provide a “hotter” spark vehicle cranking to promote easy starts. DELCO TYPE solenoids (including most foreign types) usually have a second winding (the “Pull-In Coil”) in addition to the “Hold-In Coil”: The current draw of these two coils must be checked separately. Delco type solenoids may also have an “Auxiliary Contact” terminal po:t (marked “R”). The energizing or “switch” terminal post is marked “S”. Tester Features… * Coil Selector Switch … located on the lower nght hand pancl sets Tester to check either “PULL-IN” winding (switch set to right) or “HOLD-IN” winding (switch set to left). * Voltage Selectors Switch … is located just to the left of the HOLD-IN PULL-IN Switch UP Is 24 volts – DOWN is 12 volts. * Test Switch 1 … is located on the lower panel far Jeft. This switch supplies power to the CONTACT TESTING circuit in the Tester. * Test Switch 2. is located just to the right of Test Switch | provides power to the COIL TESTING circuit. * Meter … bas a range of 0-50 amps (D.C.) and reads current drawn by winding bein: tested. ) * Left Hand (Red) Indicator Light .. glows during test when there is BAD (or no) CONTACT in the MAIN CONTACT circuit belween the heavy terminal posts of the solenoid (Heavy Red and Heavy Black Test Clips). * Center (Green) lodicator Light … glows during test when there is GOOD CONTACT in the MAIN CONTACT circuit. * Right Wand (Green) Indicator Light … glows during test wien there 1s GOOD CONTACT in the AUXILIARY CONTACT circuit * Circuit Breaker .. located in the center of the lower panc} will “pop out” if coil cnergizing circuit is overloaded or “shorted”. Breaker may be re-set (by pushing pin in) aftec short has been removed. Testing Ford Types Solenoids – Place solenoid to be tested on aluminum test plate. Mounting feet of solenoid should be tow ards you just like in the picture. Hold solcnoid firmly against test plate. This ensures good contact with the plate for proper operation. Connect Test Leads as follows …. Large Red to large copper input post on right (Batt. ). Large Black to large copper output post on Icft (Starter). Small Red to to small silver terminal post on right (Key Switch). Green to small silver terminal post on the left (Aux. Contact) if present. YESTING – Set selector Switch to its left (hold-in) position. STEP 1 – Depress Test Switch 1. Red Contact Condition light should come ON. Anv other light indicates sticking contacts and, therefore, a defective solenoid. STEP 2 ~ Keeping Test Switch | down, press down Switch 2. Left Hand (Red) Indicator Light should go OUT Center (Green) Indicator- Light should come ON indicating good “Main Contact” Right Hand (Green) Indicator Light should come ON indicating good “Auxth:ry Contact” (if solenoid has an “Aux” terminal). Mcter should read between 3 and 5 amps. Large Grecn -* Pld Delco typ : 13) sulcapicd Testing Delco Type Solenoids – Place plunger into solenoid. Place solenoid on aluminum test plate with cap facing up (see diagram on Tester). ie Connect Test Leads as follows (see diagrasm to right) … L Large Large Red Test Lead to large rear copper input (“Batt.”) Black & Cinal terminal post. Red Large Black Test Lead to large front copper (“Motor”) terminal post. Note – Ihe “Motor” post is usually very short so the Test Clip holds best when mounted VERTICALLY on the post. Small Red Test Clip to silver terminal screw (“S”) on right. Green Test Clip to silver terminal screw (“R”) on lefi. TESTING PULL-IN WINDING Set Coil Selector Switch to its nght hand (Pull-In) position. STEP 1. Depress ‘lest Switch t. Red Contact Condition Light should come on. No other lights should be on. STEP 2. While holding Switch 1 down, press down Switch 2. Plunger should be pulled into solenoid. Left Hand (Red) Indicator Light should go OFF. Center (Green) Indicator Light should come ON indicating good “Main Contact”. Right Hand (Green) Indicator Light should come ON indicating good “Auxiliary Contact”. Meter should read between 20 and 27 amps. NOTE – Lumit test to 5 seconds to avoid damage to solenoid. TESUNG HOLD-IN WINDING Set Coil Selector Switch to its le{t hand (Hold-In) position. Hold solenoid finnly against test plate. Repeat tests as with “Pull-In” winding. Ail Indicator Lights should read the same as ir: the “Pull-In” test, but the Meter should read between 13 and 17 amps.

File Type: pdf
File Size: 3 MB
Categories: manuals