Sais MS DS Ds Tn CR Dn NS GY DO QT OO OM INSTRUCT FOR ma & » ey NELSON TESTER CORPORATION | 1322 DAVID STREET WATERLOO, IOWA 50705 omom ce j — J mm oo oc} os om mmm INSTRUCTIONS FOR NELSON ELECTRICAL LEAKAGE TESTER WHEN TESTING ELECTRONIC COMPONENTS ON ELECTRICAL SYSTEMS, CHECK MANUFACTURERS SPECIFICATIONS FOR PROPER TEST PROCEDURE. CAUTION HIGH VOLTAGE USE WITH CARE READ INSTRUCTION BOOK BEFORE MAKING TESTS Place short end of test leads in test Jacks, long ends are fer making contact with items or circuit to be tested. Test light position uses approximately 100 volts. Leakage and High Test Positions supplies several hundred volts, this is used to break down intermittent shorts and grounds. Use care in handling test prods. Do not make bodily contact with metal tip of test prods or circuit | under test. Test voltages are such that no harm is done to wiring or parts that are in normal condition. WE HAVE HAD A NUMBER OF COMPLAINTS ABOUT THE SERVICE GIVEN AT MANY OF THE SERVICE CENTERS. THEY ARE INDEPENDENT SERVICE PEOPLE AND WE HAVE NO CONTROL OVER THEIR ACTIONS. -HERE AT THE FACTORY WE GIVE ONE DAY SERVICE AND CAN ASSURE YOU THAT WE HAVE THE CORRECT PARTS IN STOCK. SEND TESTER TO NELSON TESTER CORP.,1322 DAVID ST., WATERLOO, IOWA 50705 BEFOR®S SENDING UNIT TO A SERVICE CENTER,WRITE AND GET A REPLY. OEE TT a IN Sw NELSON GENERAL INSTRUCTIONS TESTER COMPANY INC. INDEX I&2 SUGGESTED PROCEDURE FOR MOTOR TUNE-UP 3 HIGH TENSION PARTS TESTED ON THE VEHICLE: MOTORS USING RESISTOR PLUGS 14 & I5 DISTRIBUTOR CAP & COIL A& 5 DISTRIBUTOR CAP & ROTOR 6& 7 WIRES & PLUGS yo & II HIGH TENSION PARTS TESTED OFF THE VEHICLE: DISTRIBUTOR CAP ~ I6 & 17 WIRES & PLUGS I8 COIL TOWERS & ROTORS 19 TESTING HIGH TENSION CARBON AND METAL WIRES FOR OPEN ON VEHICLE: I2 & 13 LEAKAGE TESTS ON THE VEHICLE: DISTRIBUTOR CAPS & PLUGS 8& 9 IGNITION LINE AND COIL 22 ACCESSORY LINE 29 GENERATOR TO REGULATOR TEST (SPECIAL NOTE 2) 21 OUT BOARD & SMALL GASOLINE MOTORS 38 & 39 GENERATOR & STARTER MAGNETOS BATTERY LINE cunck. DIRECTIONAL SIGNALS AUTOMATIC SHIFTS AND OVERDRIVES : CHRYSLER PRODUCTS WARNERS OVERDRIVE R-10 & II, FORD, GENERAL MOTORS, NASH & STUDEBAKER LIGHT LINE CHECK HYDRO-LECTRIC WINDOWS ELECTRIC WINDOWS AUTO AIR CONDITIONING SERVICE CENTERS INSIDE BACK COVER. 20 32 24 26 28 36 30 23 40 21 33 25 27 29 35 37 3I —) to Co A PE ee ) cc ca Se ee Se 7 cc – “a ao aco f= eC Cc co om L aneeeenessstpeatiiefenind se inteneemen—yseineereanennnonasentateertie eeeecioeee CAUTION HIGH VOLTAGE— ON LEAKAGE AND HIGH POSITIONS— USE WITH CARE a ee ne eee Sennen RE ee gente giee e _ Instructions for Nelson’s Deluxe Leakage Tester __ ‘40 VOLT AC OR 6 VOLT BATTERY MODEL Kaan Leakage resreg MODEL A OPERATES ON ANY 110 AC 60 CYCLE CURRENT. MODEL C OPERATES ON ANY 6 VOLT BATTERY. Test Light bulb (GE NE-51) on 110 volt AC model. On 6 Volt battery model (MAZDA NO. 47-Six Volt bulb). 3— Leakage test tubes (GE NE-51) on 110 volt AC and also on six volt battery model. To replace tubes unscrew plastic cap. Tubes have bayonet base. Red test lead jack. Black test lead jack. High tension lead. (use either 4 or 5 ground test lead for of/ the Vehicie High Tension test). TURN SWITCH TO OFF POSITION WHEN NOT IN USE. THIS UNIT WILL TEST CIRCUITS OF ANY VOLTAGE-6-12-24 & etc. USE TEST LEADS NUMBERS 4 and 5 ON FIRST THREE TEST POSITIONS OF ROTARY ‘SWITCH. HIGH TENSION POSITION USE TEST LEAD NUMBER 6 ee: ee CRS NELSON TESTER CO., INC. (Page 1) BEFORE AND AFTER EACH POSITION OF SWITCH, TOUCH END OF PRODS TOGETHER TO FAMILIARIZE YOURSELF WITH TYPE OF TEST DESIRED. USE TEST LIGHT for continuity check and to show solid grounds. LEAKAGE TEST indicates partial grounds or defective insulation. ALL PRIMARY CIRCUITS, Battery lines, Ignition lines, Armatures, Fields, and Coils (with metal cases) have a normal amount of capacity leakage. They will show a faint steady glow, on leakage tube, if good. A bright or jumpy glow on any of these parts in- dicates defective insulation. If insulation is defective, turn “Rotor to high” to see if it will “Smoke or Buzz” out. If it does not locate defective insulation turn to test light position for ground check. If circuit is grounded unhook and check parts separately. ALL HIGH TENSION PARTS SUCH AS PLUGS, WIRES, CAPS, ROTORS, ANY CHANGE OF GLOW (ON LEAKAGE TUBE) INDICATES DEFECTIVE PART OR PARTS. ALL LEAKAGE TUBES are shunted out when Rotor switch is on high position. HIGH POSITION is used to smoke out defective insulation. DO NOT USE ON HIGH OVER FIVE SECONDS ON SOLID GROUNDS HIGH TENSION position is used on all high tension wiring and parts. (distributor caps, rotors, coils, plugs and wires) To have indicator No. 3 show hidden spark jumps use ground test lead to motor and contact number 6 prod to wire under test. Flashing or steady light indicates defective insulation, This position may be used to show primary wires that have broken insulation and intermittently touches.the frame. DO NOT USE HIGH TENSION TEST MORE THAN 10 MINUTES AT A TIME. ALLOW HIGH TENSION TEST TO COOL FOR 10 MINUTES AFTER 10 MINUTES . SE OF USE WILL NOT CALL FOR COOLING PERIOD. USE. SHORTER PERIODS NELSON TESTER Co., INC. (Page 2) ‘ Co Co) CO Ce Ce Co co co