aloe | Spracehlge Control, Inc. Field Coil and Solenoid Tester 1) Oscillator Switch 2) Meter Overload Light 3) Meter 4) Gain Control 5) Atenuator Switch 6) Input Jacks 7) Power Light 8) Power Switch 9) Field Coil Wand 10) Solenoid Wand – P/N 209905 SEL ENTERPRISES RICHARD & BARBARA VENSEL. (815) 459-0355 {e00) 662 -6099 Website: www.reman.com/vensel E-mail: www.vensel7 @ aol.com 3710 RIVERSIDE DRIVE CRYSTAL LAKE, ILLINOIS 4USA 6001 FAX (815) 459-0442 AUTO ELECTRIC EQUIPMENT SUPPLIER Field Coil and Solenoid Tester P/N 209905 Block Diagram METER AMPLIFIER ATTENUATOR | | AMPLIFER GAIN GAIN — ATTENUATOR | SYSTEM SYSTEM FIELD COIL WAND _ SOLENOID WAND INPUT JACKS INPUT JACKS ? TO COIL BEING TESTED TO COIL BEING TESTED This combination Solenoid and Field Coil Tester tests either one separately, both at the same time or, in the case of a Solenoid that has two windings, both windings at the same time. The tester consists of the following: An oscillating system terminating in a Solenoid Tester Wand An oscillating system terminating in a Coil Tester Wand Two separate amplifier circuits with gain control, meters, attenuators and attenuator switches A switch on the front panel is used to select Solenoid Tester, Field Coil Tester or both. This turns on either oscillator or both as desired. The amplifiers are always on when the power switch is on. The tester operates on a 3 wire circuit 115V, 60Hz Plug three prong plug into proper receptacle for same, Do not use a three to two plug adaptor. This tester is designed to test Solenoid and Field Coil windings for shorts between layers of windings, shorts of adjacent windings and grounds to the case. Setting Up For Testing For both Solenoid and Field Coil testing, the set point (position of amplifier gain knob and attenuator switch) should be arrived at by using a known good Solenoid or Field Coil of the type or model to be tested. Switch the power switch on and allow a few minutes for warm up. Switch the attenuator switch to normal and turn the gain control to position 5 on either one to be used or both if both are to be used. Attach the leads from the input jacks to the contacts of the coil to be tested. Turn the left-both-right switch to the appropriate position and locate the wand properly. If the pointer on the meter is to the left of the o.k, position, turn the gain knob to the right until the pointer is in the o.k. position. If the pointer is to the right of the o.k. position, turn the gain knob to the left until the pointer is in the o.k. position. When the pointer is in the o.k. position, log number indicated hy gain control knob. This is your set-point position for that type of coil and can be used for future testing. Tf two (2) adjacent turns is a coil are shorted the pointer on the meter will fall way to the left of the o.k. position. Good coils will fallin the o.k. position. Field Coils or Solenoid Coils may be tested either in the case or out of the case but the set-point must be found the same way (in or out of the case) as the testing is to be performed. Keep the wands in the same relative position when testing out of the case as as they are when testing in the case. For testing some coils it may be easier to adjust the gain with the attenuator switch in the + 4 or +20 position. If the set-point is found with the attenuator switch in other than the normal position, log this along with the knob position for future use. The attenuator switch in the divide by 4, or divide by 20, position actually divides the signal gain by whichever number it is on. Shunt coils usually have a high output and thus would require the use of a lower gain control which would make adjusting less sensitive and easier to use. Putting the switch in the divide by 4 or divide by 20 will accomplish this. Oscillator switch (left, right, or both) Switch on left: Field coil oscillator on Switch on right: Solenoid oscillator on Switch on both: Field coil and Solenoid oscillator on With switch on both, it is possible for one (1) person to test field coils while another tests solenoids. NOTE: Meter overload lights are to the right of each meter. On bright indicates that the meter is being overdriven, or more output is getting to the meter than sould, with the same type or model as was used in getting the set-point. This could happen if a 24V solenoid or coil was put on when you were set up for 12V. The brightness of the light increases with the signal level so it is possible to have a very dim light in the o.k. area. SET UP FOR TESTING SOLENOIDS WITH TWO WINDINGS (Pull in and hold in) #1114468 & 114348 Solenoid Test Block Diagram AMPLIFIER GAIN SYSTEM AMPLIFIER . GAIN SYSTEM JUMPER WIRE (BLACK TO BLACK) romse RED © ( YBLack RED (|) f= : | “S” OR “SW” ASE MOTOR C4. SOLENOID | OSCILLATOR LACK WAND SHOULD GO ALL SOLENOID . THE WAY INTO THE COIL If the solenoid being tested is too small to accept the wand with the cover on the front end of it, remove the cover. This will then go into a diameter of .800”. Take care not to damage the coating over the windings on the wand when using it without the cover and use it with the cover on when possible. For best results in all tests, it is best to have everything set up the same way for testing as it was in arriving at the set point.