VAT-40 Volt Ampere Tester Operators! AMMETER ELECTRICAL ZERO ADJUST MECHANICAL ZERO ADJUST VOLTMETER VOLT SELECTOR= MECHANICAL ZERO ADJUST FIELD SELECTOR LOAD INCREASE. * CONTROL LOAD LIGHT TEST SELECTOR: TEST LEADS: Figure 1—Volt Ampere Tester Model VAT- 40. TABLE OF CONTENTS GENERAL INFORMATION PAGE Meter Mechanical Zero Adjustment……….. 1 Ammeter Electrical Zero Adjustment………. 1 Ammeter ………0…0.00 0000 eee ewan 1 Voltmeter… 0. eee ees 4 Volt Selector …………….. Lecce ee ee eaee 1 Field Selector ….. 0.0.0.0 .0 cece eee ee eee | Load Increase Control Knob …………..0.. 1 Load Light……… 0… cee eee eee 1 Test Selector… 0… teens 2 Field Lead .:…… cece eee eee e nee 2 External Voltmeter Leads ……………0.. . 3 Clamp-on Ammeter Pickup……………… 3 Load Leads …… 0… eee 3 Tester Supply Voltage ……………..00… Lo . CONDENSED TESTING PROCEDURE “ General Test Conditions ……………….. 4 Calibration And Hookup …….. cece eee eee 4 Test #1 Starting…………..0……… te… 4 Test #2 Charging………….. 0.00 eee eee 5 Test #2A Output Test Using Field Selector….. 6 Test #3 Voltage Regulator………………. 7 Test #4 Diode Stator… 0… eee ee 7 STARTING SYSTEM TESTING Testing Principles ……… 00.0. cece eee eee 8 Battery Performance Load Test …………. 2 8 Starting System Area Tests……………. 1. 8 Starting System Detailed Testing. ……..-… 8. Tester Preparation 2.0.0… GO Battery Test….. eee e eee eet eee beeen 9 Starting System Test ……………..0.. 21. 9 insulated Circuit Resistance Test ………… 9 . Ground Circuit Resistance Test ………….. 11 Switch Circuit Resistance Test…………… 14 CHARGING SYSTEM TESTING Testing Principles ……….. Lecce cece e ee 13 Alternator Testing ©… 0.06. ee eee 43 Compleéte Charging System Tester ……0..0. 13 . Charging System Detailed Testing…….. ….18 Test #2 Charging System………………. 13 Test #2A Output Test……………2..0000. 14 Voltage Regulator Test #3… 2… …..000.. 15 Diode Stator Test #4…………. aces 12.015 Charging Requirements Test #5………….. 15 Circuit Resistance Test ………………… 16 Insulated Circuit Resistance Test ………… 17 i – } . | i ‘ . ‘ ’ . . te SUN’S 3-MINUTE BATTERY TEST DOES NOT APPLY TO MAINTENANCE-FREE BATTERIES Quickly determines whether a 12 volt battery is GOOD …CHARGEABLE.. . or NO GOOD IMPORTANT Wear safety glasses and observe safety precautions-see other side. if battery temperature is not between 60° and 100° F, allow temperature to normalize before making these tests. VISUAL INSPECTION If battery is in good condition add distilled water as If the battery has loose posts, cracked case or top, the needed and continue test. battery is NO GOOD CAPACITY TEST 2 CHARGE TEST (Perform only if battery tails Capacity Test.) Connect a Sun Tester and load the battery as specified’ Connect a voltmeter and a Sun fast battery charger. Set by the manufacturer for 15 seconds. Note battery charge rate as close as possible to, but not over, 40 voltage while under load. ~ amps. Note voltage after 3 minutes. If the voltage remains If the voltage drops Voltmeter reading Voltmeter reading goes above 10 volts, battery below 9.6 voits, perform Stays below 15.5 over 15.5 volts, battery is GOOD 3 Minute Charge Test volts, proceed to cell isNO GOOD test Under Charge. If the voltage is between 9.6 and 10 volts, perform Cell Test Under Load CELL TEST UNDERLOAD § CELL TEST ON CHARGE 1. Connect cadmium cell probes (BCP) to voltmeter 1. Connect cadmium cell probes (BCP) to voltmeter leads. Set voltmeter to low range. leads. Set voltmeter to low range. 2. Apply specified” load. ee 2. With the voltmeter and fast charger connected and mPharninn mt tym cama rata ac AMA Oremmnsrt than Pei a. Read the cell voltage of cell #1. b. Remove the load. 3. Repeat step 2 for each cell. Note: See other side for cell voltage test sequence. If the call voltages If the cell voltages are even within 1/10 vary by more than 1/10 volt, battery is GOOD volt the battery is ‘y NO GOOD CHARGE Charge until fully charged. Refer to Charging Rate Table. After battery cools, perform CAPACITY TEST. If voltage under load is 10 Hf voltage under toad is volts or more, battery is less then 10 volts, battery GOOD is NO GOOD charging at the same rate as ahove, réad tne cell voltage of cell #1. 3. Repeat step 2 for each cell. Note: See other side for cell voltage test sequence. if the cell voltages If the cell voltages are even within 1/10 vary by more than 1/10 volt battery is volt the battery is CHARGEABLE NO GOOD THE BATTERY CHARGING RATE TABLE Specific Gravity at 80°F Charging Rate/Time 1.150 or less 40 amps/45 minutes 1.150 to 1.175 40 amps/30 minutes 1.175 to 1.200 40 amps/20 minutes 1.200 to 1.225 40 amps/10 minutes above 1.225 slow charge SPECIFIC GRAVITY TEST INDICATIONS GOOD A battery may be returned to service when the specific gravity of all cells is above 1,250 and the difference between cells is less than .050 for dry charged batteries, 030 for wet charged batteries. NO GOOD A battery is unsuitable for service if, after being charged, the specific gravity is below 1.250 or there is more than .050 difference between cells for dry charged batteries, .030 for wet charged batteries. “For specified battery loads, see applicable Suntesters or Battery Manufacturer’s Service Bulletins. Optional— Use % of Cold Cranking Current Rating at O°F, or 3 times A.H. Rating.

File Type: pdf
File Size: 29 MB
Categories: manuals