CPR ES ath Pat sree Lala ae : ne v ‘ yf ¥ “OPERATING MANUAL pe ae _WEIDENHOFF. MODELS 500 and 501 Bo Stearn | ST BENCH P ‘ JOSEPH WEIDENHOFF, INC.) J 5 CHICAGO 24,4LL. SPECIFICATIONS Model 501 Master Cyclone Test Bench |. Motor: Maximum h.p. de- veloped, 7.1. Intermittent duty rating: 5 h.p. developed on trans- mission output shaft at 1150 r.p.m. in low gear (ratio 22:36) or at 2100 r.p.m. in high gear (ratio 31:17). Testing generators by belt drive, with 2:1 pulley ratio, peak h.p. is reached at generator speed of 2300 r.p.m. in low gear, at 4200 r.p.m. in high gear. Test- ing generators directly coupled to transmission output shaft, 5 h.p. or more is available for generator speeds of 450 to 4050 Y.p.m. Testing belt driven with 2:1 pul- ley ratio, 5 h.p. or more is avail- able for speeds of 900 to 8100 r.p.m. Directly coupled 3 h.p. or more is available for speeds of 300 to 5800 x.p.m. belt driven with 2:1 pulley ratio for speeds of 600 to 11,600 p.m. Motor four pole brush shifting type for 220 volt, 60 cycle, | phase A.C. 2. Transmission: Specially de- signed for this test bench. Cast integrally with drive end housing of motor. Gears shifted by self- locking lever mounted on side of case, easily accessible. Neutral position provided, also large ball bearings lubricated by oil bath. 3. Speed Control: Motor brushes shifted to control speed. Shift lever located above trans- mission in front of panel. 4. Chasis: Entire assembly sup- ported by heavy cast iron pedes- tal. Movable table raised and lowered by screw control on accu- rately machined “‘V’’ ways with gib to adjust for wear. Horizontal movement of table top controlled by lead screw. 5. Bench Top: 14-inch ply die stock, first quality hardwood. Steel upper plate protects table top and contains dowel pin holes for aligning ““V”’ blocks. 6. Mounting: Clamp arm holds generators and starters up to 10 inch diameter in “V’’ blocks for testing. |’/-inch cold rolled steel post supports clamp arm. Two rows of dowel pin holes are used: one for mounting for direct drive, the other for belt drive. 7. Drive: Generators tested both directly coupled to output shaft of transmission or by belt drive. Direct coupling is made with a self-centering “‘“dog’’ which clamps on generator armature shaft. Belt driven generators are tested by means of a pulley per- manently mounted on output shaft of transmission. Two pulleys with demountable hubs furnished for mounting on generator shafts not equipped with pulley for testing belt driven if desired. Large pulley 7.4 inch pitch diameter for “‘B” section belt, small 3.6 inch pitch diam- eter. Nine assorted pulley hubs are furnished for mounting pulleys on generator shafts not equipped with pulleys. Special adapters can easily be made by purchaser at small cost. 8. Tachometer Coupling : Coup- ling connects tachometer cable to generator shaft, showing true gen- erator speed. Contact with shaft is made by ‘sponge rubber disc held in cup adapter. Tension by coil spring. Unit is self-centering; Model 501 Master CYCLONE Test Bench no cumbersome adjustment. When testing generators directly coupled to transmission output shaft, tach- ometer cable is driven by an end- less belt. Take-off is from trans- mission output shaft. 9. Motor Switch: Start stop switch integral with speed control lever. 10. Panel: Constructed of heavy ‘Masonite’, with screened bo lettering and decorations. Modern design. 11. Voltmeters: D’Arsonval heavy-duty, jewel or glass bearing type with knife-edge pointer. Me- ter face, 7 inch diameter; bezel 8! inch diameter. Calibrated 0-10 volts in 1/10 volt graduations, 0-20 volts in 1/5 volt gradua- tions and 0-50 volts in 1/2 volt graduations. Metal, non-warping dial. 12. Ammeter: D’Arsonval heavy-duty, jewel-bearing type with knife-edge pointer. Meter face and bezel same diameter to match voltmeter. Calibrated 2-0-10 amps. in 1/5 amp. gradu- ations, 10-0-50 amps. in | amp. graduations, 40-0-200 amps, in 4 amp. graduations and 200-0- 1000 amps. in 20 amp. gradua- tions. Metal, non-warping dial. 13. Tachometer: 5 inch face, calibrated 0-8000 r.p.m. Right and left rotation. Zero adjustment provided. Flexible cable drive. Indicates actual generator speeds. Metal, non-warping dial. 14. Series Test Lamp: Mount- ed back of panel. Ruby lens in panel illuminated when lamp burns. Telephone jack with test prods furnished to plug into panel for tests. 15. Terminal Connections: Six screw-type binding posts. All plainly marked for making proper connections. 16. Series Carbon Pile Rheo- stat: For placing variable resis- tance in series with generator. With load carbon pile rheostat provides load on generator with- out need of batteries. With series carbon pile it is possible to apply gradual voltage for starting motor tests or exact voltage desired at starting motor terminal. Heavy- duty carbons used in construction. Ruggedly built. 17. Load Carbon Pile Rheo- stat: Places load across batteries to simulate low-voltage condi- tions. Also used with Series Car- bon Pile Rheostat. 18. Field Control Rheostat: For adjusting field current for manual control of generator on test at all speeds. Field circuit protected by overload relay to prevent damage by overload to ammeter and rheostat. 19. Voltage Selector Switch: Four positions to select proper voltage for unit being tested—6, 12, 24, and 32 volts. 20. Series Carbon Pile Rheo- state Switch: Single pole single throw, 100 ampere constant duty rating for connecting series carbon pile in or out of circuit. 21. Load Carbon Pile Rheo- stat Switch: Single pole, single throw, 100 ampere constant duty rating. 22. Polarity Switch: Double pole, double throw, 100 ampere constant duty rating. 23. Field Circuit Selector Switch: Single pole, double throw, 35 amp. constant duty rating for mechanical strength. 24. Voltmeter Scale Selector Switches: Six push button type. For selecting proper scale and po- larity—I0, 20, 50 volts, positive or negative ground. Has six pilot lights, indicating scale selected; 3 green for negative, 3 red for positive. 25. Ammeter Scale Selector Switches: Eight push button type. For selecting proper scale and po- larity—1000, 200, 50, 10 amps. positive or negative ground. Has eight pilot lights, indicating scale selected; 4 green for negative, 4 red for positive. 26. Shunts: Laminated ‘“‘Man- ganin’ for 1000 and 200 amps. scales. Other shunts, strip or wire “Manganin’’, mounted on back of panel. !