Pump Motors SERVICE cs INFORMATION ___(Issued 3-16-78) _ @, prestolite,_“0x__ VOLTAGE 24 ROTAT ION CWDE BRUSHES 4 POLES 4 VENT ILATED No FRAME DIAMETER 5″ BEARINGS Ball bearings used at both ends. LUBRICAT ION Both ball bearings are prelubricated and sealed. No lubrication required, BRUSH REPLACEMENT Replace brushes when they have worn to a length of 1/4″ or less. SPRING TENSION 25 to 44 ounces with new brushes. Measure with a spring ~ scale hooked under the brush spring at the brush. Pull the scale on a line opposite the line of force exerted by the brush spring and take the reading just as the spring leaves the brush. END PLAY Adjust to .005″‘ to .035′”‘ with thrust washers between the C.E. bearing and the retaining snap ring. Refer to Parts § Equipment List for thrust washer package. TEST SPECIFICATIONS (77°F) Terminal Maximum Torque oo, Voltage mperes RPM Ft. Lbs. No Load Test 22 14 5600 Min. —- Stall Torque Test 8 Unit MDX – 4001 VIEWED FROM COMMUTATOR END INTERNAL WIRING DIAGRAM File in the | PUMP MOTOR SECTION | printed in US A L600 SERVICE MANUAL ==>