@ prestolite x ____ Pump Motor SERVICE Page 1 of 1 _ INFORMATION tesued 3/16/78 VOLTAGE 36 ROTATION CCWDE BRUSHES 8 POLES 4 VENTILATED No FRAME DIAMETER 7-1/8″ LUBRICATION None required. Prelubricated and sealed ball bearings used at both ends of motor. BRUSH REPLACEMENT Replace brushes when they have worn to a length of 9/16″ or less. SPRING TENSION 30 to 36 ounces with new brushes. Measure with a spring scale hooked under the brush spring at the brush. Pull the scale on a line opposite the line of force exerted by the brush spring and take the reading just as the spring leaves the brush. COMMUTATOR Minimum diameter 2.938″. Replace armature when commutator has worn to this dimension. SHUNT FIELD RESISTANCE 3.56 to 3.94 ohms measured between terminals (77°F / 25°C) “FR” and “A”, TEST SPECIFICATIONS (77°F/25°C) Terminal Maximum Torque Voltage Amperes RPM Ft. Lbs. No Load Test 36 27 2600 Min. -O- Stall Torque Test 34.83 82 2380/2640 5 “ps Unit Ss 4 MFH-6001,S SHUNT WINDING VIEWED FROM COMMUTATOR END 1 4Nn CERPVICFE MANUAL => Pump Motor Section