Printed in LIS A restolite MLM INV Traction Motor SERVICE Page 1 of 2 INFORMATION __Issued 10/29/86 VOLTAGE 24 #RCTATION Reversible BRUSHES 4 POLES 4 VENTILATED Yes FRAME DIAMETER 6-5/8″ LUBRICATION None required. Prelubricated and sealed ball bearings used at both ends of motor. FIELD RESISTANCE (77°) .0045 to .0050 ohms measured between terminals S-1 and S-2. ARMATURE TEST This armature has standard winding connections and can be. tested on a growler to locate shorted windings. COMMUTATOR Minimum diameter 2.938″. Replace armature when commutator has worn to this dimension, BRUSH REPLACEMENT Replace brushes when they have worn to a length of 9/16″ or less. SPRING TENSION 30 to 36 ounces with new brushes, Measure with a spring scale hooked under the brush spring at the brush. Pull the scale on a line opposite the line of force exerted by the brush spring and take the reading just as the spring leaves the brush. TEST CONNECTIONS CWDE CCWDE Connect S-2 to battery positive Connect S-1 to battery positive Connect S-1 to A-2 Connect S-2 to A-2 Connect A-1 to battery negative Connect A-1 to battery negative TEST SPECIFICATIONS (77°F) Test in both directions of rotation. Terminal Max imum Torque Voltage Amperes RPM Ft. Lbs. No Load Test 12 21 2400 Min. – 0- INTERNAL UNIT WIRING MLM-4001,5 Figure 1 MLM-4002,5 Figure 1 MLM-4003 Figure 2 Fite in the 1-400 SERVICE MANUAL ==> | TRACTION MOTOR SFCTTON | MLM Traction Motor IX prestolite. Page 2 of 2 SERVICE Issued 10/29/86 INFORMATION FIG. 1 FIG. 2 VIEWED FROM COMMUTATOR END