©, prestolite._â„¢* Pump Motor SERVICE Page 1 of 1 INFORMATION ______Issued 11/29/79 _ VOLTAGE 36 ROTATION CWDE BRUSHES 8 POLES 4 VENTILATED Yes | DIAMETER 7-1/4″ BEARINGS Bali bearings used at both ends. LUBRICATION None required. Prelubricated and sealed ball bearings used at both ends of motor. BRUSH REPLACEMENT Replace brushes when they have worn to a length of 9/16″ or less, SPRING TENSION 30 to 36 ounces with new brushes. Measure with a spring scale hooked under the brush spring at the brush. Pull the scale on a line opposite the line of force exerted by the brush spring and take the reading just as the spring leaves the brush. ARMATURE TEST These armatures have standard winding connections and can be tested on a growler using a metal strip or hacksaw blade to locate shorted windings. COMMUTATOR Minimum diameter 2.938″. Replace armature when commutator has worn to this dimension. FIELD RESISTANCE (779F/25°C) .0028/.0034 ohms measured between terminals “S” and field armature strap connector. SHUNT. RESISTANCE (770F/25°C) 21.47/23.73 ohms measured between terminal “S” and “A”. TEST SPECIFICATIONS (77°F /25°C) Terminal Maximum Torque Voltage | Amperes ———_—saRPM – Ft. Lbs. No load test 36.0 27.0 3650 ~0- Light Load Test 34.5 155.0 2550 to 2950 10.0 Unit MLY-4001 xg me MLY-4002 iG SHUNT WINDING. VEE SOM COMMYTATOA LT ND File in the | 1 4NN CERVICE AANUAL = Pump Motor Section