C—O Bulletin FM183 FAIRBANKS-MORSE ] INSTALLATION OF MAGNETO VENT WS ss; ce A6032FC VENT & SCREEN DRILL FOUR 7/64″ HOLES — USE #6-32 TAP IN CENTER HOLE After considerable field research, we have found to eliminate moisture and oil fumes a vent should be installed, as illustrated above, on the following type magnetos: FM-J1B2A FM-J1B2B FM-X1B2A FM-X1B2B Drill a 7/64″ hole in the center of the bottom 1” from the front edge of frame. Thread this hole using a #6-32 tap. Then drill three 7/64″ holes, as shown, approximately 1/4″ apart and cover with vent and screen assembly A6032FC. On all shipments now being made, our vented type magnetos are substituted for those listed above. Type FM-X1B2C replaces FM-X1B2A, and FM-X1B2D replaces FM-X1B2B. Fairbanks, Morse & Co. Magneto Division Bulletin FM 183 387582-095175C-BDN Sept. 15, 1951 Printed in U.S.A. File Section – TYPE FM-J