ERA Office: Monday – Friday 9:00-5:00 CST

275 W. BROWN ST, UNION, MO 63084

636-584-7400

office@electricalrebuilders.org

ERA Tech Helpline: 636-584-TECH (8324)

Instructions No. 2850D Supersedes Instructions No.2850C and 2888B eo ) Fig. 1. Type FM-J1 Magneto and Mountings. GENERAL DESCRIPTION Modern ignition systems are carefully designed to provide quick, easy starting and maximum dependability of operation without adjustment or service. Through advanced engineering, together with sturdy construction, Fairbanks-Morse Type FM-J magnetos have become field performance leaders. Especially co ct in assembly, the powerful Alnico rotor assures an intensely hot ig- nition spark even under the most difficult operating conditions. Although field adjustments are simple, they are rarely necessary and should be made only in accordance with the following instructions. APPLICATION use on tion spark Vi Available for count spoloaliniae:& otation, these magnetos are bui it for 3 both base and flange mounting, with the base- -mounting i made suitable for? oth the 35- and )5-mm. shaft thr base adapter plates. On shaft height the Type UC lse coup i equipment, while the )5—m. , is equipp ad with the Type UA2 cour r Type FM- agnetos are also furnished without A two-pole magnetic rotor, toget single lobe breaker cam, provides a single spark per revolution. Magnetos on one cylinder usually operate at crankshaft speed. TROUBLE ines eng POSSIBLE CAUSE SERVICE PROCEDURE The table below gives avery logical procedure to follow when an engine fails to start, is hard to start, or misses in operation. Since the use of this table locates the trouble in many cases before the magneto is reached, it prevents all-too-common maladjustment of parts in good condition. Type FM-J magnetos are built in sealed housings which should be opened only when it is certain that the ignition spark produced is unsatisfactory This condition may be determined through ignition spark tests which are easily made in the field. TESTING THE IGNITION SPARK With a properly dition, the ignition adjusted spark plug in good con- spark should be strong enough to bridge ashort gap in addition to the actual spark plug discharge. This may be determined by holding the end of the ignition cable not more than 1/16 in. away from the spark plug terminal. The engine should not miss fire when this is done. Ignition tests made while any part of the system is wet are useless. TESTING THE MAGNETO SPARK Remove the ignition cable from the end cover socket and insert ashort piece of stiff wire. Bend this wire to within 1/8 in. of the engine block. Turnthe engine over slowly and watch carefully for the spark which should occur at the instant the impulse coupling re- SUGGESTED REMEDY . Flooding Hot or cold engine; over-rich fuel mixture. Insufficient fuel or air Empty fuel tank; clogged fuel sup- ply line; clogged air intake. Ignition connecti Loose or corroded terminals; broken ons cables; short-circuited switch. Corroded, worn, or damaged points; cracked or carbonized insulator. Instructions No. 2850D July 1, 1948 . Spark plug Replenish fuel supply; bureter; New i commended opening; Dry out cylinder; crank engine slowly with fuel shut off; or let engine stand idle for short interval. clean fuel system and check car- clean air intake system. peas or replace cable terminals; inspect soldered or clamped} ts; test and replace cable; check ignitaon switch. lug; clean points and insulator; adjust potmt sap to re never attempt to adjust center electrode. See instructions beginning “TESTING THE IGNITION SPARK”. File Section- TYPE FM-J Page 2 2850D FAIRBANKS-MORSE TYPES FM-Jl AND FM-JEl1 MAGNETOS leases. If a strong spark is observed, it is highly recommended that the magneto be eliminated as the source of difficulty and that the cable, terminals, and spark plug be thoroughly inspected. CONDENSER LOCKING ) SGREW 7 4 MEASURE BREAKER POINT GAP WHEN OPEN. ADJUST TO 0,020 INCH AOQUJUSTING w (ECCENTRIC HEAD) BREAKER ARM TERMINAL SGREW CCW GW Fig. 2. End Views of Type FM-J1 Magneto. SERVICE OF BREAKER POINTS Remove the magneto end cover and compare the ar- rangement of parts with the drawings of Fig. 2. The breaker points should then be inspected for evidence of pitting or pyramiding. A small tungsten file or fine stone may be used to resurface the points, except in the case of badly worn or pitted points, which should be replaced. Complete replacement, when necessary, can easily be made by removing the locking screw of the contact support bracket and the terminal screw, which frees the breaker arm. If it is necessary to resurface or replace the breaker points, it will also be necessary to readjust them to their proper clearance, which is 0.020 in. at full separation. This adjustment is made by loosening the locking screw, turning the eccentric head adjusting screw until the proper gap is obtained, and then retightening the locking screw. The cam felt wick, if dryor hard, should be replaced by a new fac- tory-impregnated wick. LUBRICATION AND BEARINGS Lubrication of Type FM-J magnetos inthe field is unnecessary and inadvisable., Whena complete overhaul of the ma

File Type: pdf
File Size: 5 MB
Categories: magnetos