ERA Office: Monday – Friday 9:00-5:00 CST

275 W. BROWN ST, UNION, MO 63084

636-584-7400

office@electricalrebuilders.org

ERA Tech Helpline: 636-584-TECH (8324)

FAIRBANKS-MORSE MAGNETO DIVISION BELOIT, WISCONSIN INSTRUCTIONS 3059WA SUPERSEDES INSTRUCTION 3059W October 1957 TYPES FM-XD1IB7S AND FM-XDEIB7S MAGNETOS TYPES FM-XD1B7U and FM-XDEIB7U MAGNETOS FOR WISCONSIN MOTOR CORPORATION MODELS ACN,BKN,AEN AND AENL ENGINES GENERAL DESCRIPTION The one cylinder magnetos whose parts are listed in this instruction sheet are built specifically for applica- tion on Wisconsin single cylinder engines listed above. The magnetic and electrical circuits of both units are identical, with a two pole magnetic rotor and a single lobe cam producing one ignition spark per revolution. These flange-mounting magnetos rotate clockwise when viewed from the drive end. All are fitted with depend- able, single pawl impulse couplings which facilitate starting by providing an intensified and retarded ignition spark at low engine speeds, SERVICE PROCEDURE Improper functioning of the magneto is often believed to be the cause of engine trouble arising from other sources, such as a flooded carburetor, an obstructed air intake, defective ignition connections, or corroded spark plug points. Since a brief engine inspection will often locate the trouble before the magneto is reached, it pre- vents maladjustment of magneto parts in good condition. It is suggested that the magneto be opened only when it is certain that the ignition spark produced is unsatisfactory. This condition may be determined by simpie tests which are easily made in the field. TESTING THE IGNITION SPARK With a properly adjusted spark plug in good condi- tion, the ignition spark shouldbe strong enough to bridge a short gap in addition tothe actual spark plug discharge. This may be determined by holding the end of the ignition cable not more than 1/16 in. away from the spark plug INSTRUCTIONS 3059WA October 1957 File Section -TYPE FM-X j Service and Adjustment Information terminal. The engine should not misfire when this is done. Ignition tests made while any part of the system is wet are useless. TESTING THE MAGNETO SPARK Remove the ignition cable from the end cap socket and insert a short piece of stiff wire. Bend this wire to within 1/8 in. of the engine block, Turn the engine over slowly and watch carefully for the spark which should occur at the instant the impulse coupling releases. Ifa strong spark is observed, it is recommended that the magneto be eliminated as the source of the difficulty and that the cable, terminals, and spark plug be thoroughly inspected. SERVICE OF BREAKER POINTS Remove the magneto end cap and compare the ar- rangement of parts with the drawings of Fig. 1. The breaker points should then be inspected for evidence of pitting or pyramiding. A small tungsten file or fine stone may be used to resurface the points. Badly worn or pitted points should be replaced. Removal of worn points may be accomplished by removing the fulcrum pin snap ring, the breaker arm terminal screw, and the contact support locking screws, Fig, 1. If it is neces- sary to resurface or replace the breaker points, it will also be necessary to adjust them to their proper clear- ance, whichis .013 – .017 in. This adjustment is made in the following manner: Loosen the contact support locking screws, then move the contact support until the proper breaker point clearance is obtained. This is ac- complished by means of a screwdriver inserted in the PRINTED IN U.S.A. *Page 2 3059WA TYPES FM-XDIB7S, FM-XDE1B7S, FM-XD1B7U AND FM-XDE1B7U MAGNETOS Instructions MEASURE BREAKER POINT GaP WHEN OPEN. ADJUST TO O.O1S INCH FULCRUM PIN SNAP RING BREAKER ARM cw (0095003) End View Type FM-X Magnetos Fig. 1. horizontal slot at the bottom of the contact support and pivoted between the two small bosses on the bearing support. Lock the assembly in place by tightening the locking screws and make a final measurement of the breaker point gap after the locking screws are tightened. SEALING MAGNETOS Opening the magneto for breaker pointadjustment or other service necessitates resealing the magneto upon reassembly. The surfaces between the magneto frame and the end cap should be thoroughly cleaned and a new gasket provided. Remove the vent hoods and clean the vent screens ofallforeign material before final reassem- bly. SPECIAL DRIVE GEAR Flange mounting magnetos for Wisconsin motors require a drive gear fitted to the impulse coupling by means of an extended rotor shaft. To engage the slotted drive gear correctly with the drive lugs of the coupling, the magneto rotor should be turned by hand until the coupling pawl engages the stop pin in the flange, the coupling drive lugs then being in the position shown by A of Fig. 2. The drive gear should then be fitted to the coupling so that the marked tooth is on the upper edge of the gear as shown in B of Fig. 2. The tooth on gear GD- 113, used on AENL and AEN engines, is marked with an X onthe outer edge of the tooth and on gear GD-87-C, used on ACN and BKN engines, an I is stamped on the face of the tooth. RADIO-SHIELDED MAGNE

File Type: pdf
File Size: 4 MB
Categories: magnetos