FILE IN THE ALC PrestOltle SERVICE MANUAL ALTERNATOR SEC TION PN (Issued 3-16-78) VOLTS 12 VENTILATED Yes’ RATED OUTPUT 45 Amperes ~ BRUSHES 2 CONTROL Voltage Regulator ROTATION CWDE BEARINGS Sealed, ball at drive end. Roller at slip ring end. LUBRICATION Bearings are pre-lubricated. No additional lubrication necessary. BRUSH SPRING TENSION 9.5 to 11 ounces when spring is compressed to I/4 inch, BRUSH SPREADER TOOL When reassembling an ey —_- alternator, it will be necessary to ! : spread the brushes so that they will not interfere with the installation of . me the rotor. A tool for spreading the brushes can be fashioned out of 1/8’? welding rod or a hoofs common coat hanger. See Figure 1. Figure 1. END PLAY Negligible. Unit should rotate freely without binding. A condition of end play would indicate improper assembly, damage or excessive wear. GROUND POLARITY Negative. NOTE: DO NOT ATTEMPT TO POLARIZE AN AL. TERNATOIL- DAMAGE MAY OCCUR TO THE ALTERNATOR, REGULATOR OR CIRCUITS. ROTOR CURRENT DRAW (70°F.) 2,3 to 2.4 maximum amperes at 10 volts. QUTPUT TESTS (70°F. ) 13, I volts, 10 minimum amperes, 1250 RPM alternator speed, 14. 2 volts, 45 minimum amperes, 4200 RPM alternator speed. INTERNAL UNIT WIRING ALC-5001 Figure 2 Figure 2.