Alternator Test Console Model No. C-200-24 Operating Instructions The Alternator Test Console is used in conjunction with a separate drive motor and vise to test automotive alternators up to 200 Amp capacity. The motor must be at least 5 HP with a pulley large enough to produce 4000 RPM at the alternator. This means that, if the motor is RPM is 3450 (or thereabouts), the drive pulley should be 3-3/4 inch pitch diameter. A motor speed in the neighborhood of 1725 RPM would require a 7-1/2inch P.D. pulley. A second pulley of the serpentine type is advisable to permit full load testing of alternators equipped with this type pulley. The Console performs two important functions. First, it supplies electric power to the rotor (field) of the alternator. This field power is variable between 0 and 17 volts DC. If the field supply is shorted, the main circuit breaker will trip. The second function of the Console is to absorb the power output from the alternator being tested. This is accomplished by using high power, relay controlled, load resistors for COARSE load control and a carbon pile for FINE load control. FEATURE IDENTIFICATION – Output voltage and current are shown on the two large (upper) meters. Located directly to the left of the main voltmeter is a small switch marked “main” and “aux”. This allows switching the voltmeter from the Main (large red) test lead to the “Aux.” (green) test lead. This will be explained under “Auxiliary Output Testing”. The three lower (smaller) meters are (from left to right) Field Volts, Field Amps and Ripple Voltage. These will be explained under “Operating Procedure”. Load controls are located to the left on the upper panel. The upper black knob is the COARSE Load Control which varies the load from 0 to 175 Amps in 25 Amp steps. Below this knob is a similar black knob which is the FINE Load Control. This is a Carbon Pile which allows for infinite adjustment up to 40 Amps. Located beneath the field voltmeter and ammeter is a switch and a red corresponds to the go System dash mounted ous Volts warning light in @ systems such as the Delco 10SI and is often referred to as the “trio light”. When the toggle switch near this Fine light is switched right (toward the light) the field New En Cc grg. Co. pve: mus ran. @ through a 10 ohm Trickle resistor (like on the vehicle). This “PARTIAL FIELD” reduces the rotor current to about 1 amp and causes the red light to glow. As the alternator produces power and field current is supplied by the trio, this light will go out. The Field Ammeter will also drop to zero. Placing this switch in its center position further reduces the field current to a “TRICKLE” (about 0.1 amps) as required when testing some foreign internally regulated alternators. Setting this switch to the left restores “FULL FIELD”. When testing internally regilated alternators, if you’re not sure which setting to use, start with “Trickle”. If that doesn’t work, switch to “Partial” and finally, if necessary, to “Full Field”. eo) On the lower panel (from left to right) are found the main on-off, pilot, Battery Connect Switch and light, 12v/24v Switch, Field Control Knob, Pos/Neg Ground Switch and the various test lead cables. These switches and controls will be explained later. The small black terminal block located on right side of the Console is for connection to an oscilloscope. Operating Procedure Since this equipment may not operate exactly like older testers you may be familiar with, it will pay you to follow these instructions through once carefully. Test the same type of alternator indicated in the instructions and follow the same sequence for best results. Random jumping from one type of alternator to another or starting with the most complicated alternator in the shop usually leads to confusion, frustration and more time spent getting to know your new Test Bench. (1 ) – (Testing a 12 volt, negative ground, non-regulated, single field alternator) TEST LEAD CONNECTIONS After securely mounting the alternator to be tested, connect test leads as follows – Large Black Clip (GND.) goes to frame or mounting vise. Large Red Clip (12v main) goes to alternator main (BATT) output terminal. Small Red Clip (field) goes to alternator field terminal. Small Green Clip (aux) may be connected to the “auxiliary” output (such as the diode trio output on some Motorola alternators) or the “stator” output terminal (such as found on Ford alternators) if there is one. FIELD P R SET-UP Locate black Field Control Knob at center of lower panel and set to low (about 9 o’clock) position (5-6 volts on Field Voltmeter). – Locate 12v/24v Switch (to left of Field Control Knob) and set it to its down (12v) position. Locate “Full Field” switch on upper panel and set to left (full field) position. Locate ground switch directly to the right of the Field Control Knob and put it in the upper (NEG.GND) position. LOAD CONTROL Set Coarse Load Control to 50 Amp setting. This is a good starting point for most automotive alternators. Set Fine Load Control to minimum (about one full turn CCW from full CW (snug) position). METER SETTINGS – Set voltmeter switch to “main”. TESTING Turn Console on using the switch located to the far left of the lower panel. This switch is also a sensitive circuit breaker which protects the Console from damage due to shorts. It may sometimes trip when the machine is turned on. This is O.K. – try again. It is best to start out with reduced field power (5-6 volts) for several reasons. First, it is easier to start the motor with the alternator in low/no load status. Second, watching the Field Ammeter as the field voltage is increased gives early warning of a rotor short. Finally, starting with full field voltage against a light load (in a non-regulated alternator) will result in high system voltage which might damage some components.

File Type: pdf
File Size: 5 MB
Categories: manuals