ERA Office: Monday – Friday 9:00-5:00 CST

275 W. BROWN ST, UNION, MO 63084

636-584-7400

office@electricalrebuilders.org

ERA Tech Helpline: 636-584-TECH (8324)

PRESS for Starters. filternators. & Generators Industri ics LITTLE SWEDE EQUIPMEN? 710 E. 17th ST. WICHITA, KS 67214 ° Deg veel 316-265-7997 ALTERNATOR, STARTER, GENERATOR PRESS This press Is designed specifically for the electrical parts rebullder. It does what formerly took 4 or 5 presses to do, and even more. The press Is a rugged functional tool that fits Into both small and large operations. It operates through hydraulic pressure from an electrically driven pump which drives three Independently controlled cylinders. The vartous com- ponents of starters, generators, and alternators are removed or replaced while held In speclally designed fittings. The LS Press for Starters, Alternators, and Generators has been designed with heavy heat treated tooling. When maintained and operated as Instructed tt can provide years of efficlent operation. TABLE OF CONTENTS Page Number Safety 2 About Hydraulic Safety 3 Installation 4 Operation 5 Parts List 12 Specifications 13 Warranty 13 Copyright © 1982 LS Industries SAFETY This machine has been designed and constructed with safety as a prime consideration. Because !t Is a machine, however, It could, If mishandled or Improperly operated, malintalned, or used, have the potential for causing Injury. As LS Industries has taken steps to provide safety devices and product Information to prevent Injurtes, It cannot be held responsible for Injury to persons or property through the use or misuse of LS Industries equipment. [2 Shut power off before performing maintenance on machine. == Malntaln all mechanical and electrical parts regularly. = Always keep al! guards In place when operating. k= secure to bench, floor, or base; keep bolts tight. == Use only high flash-polnt, low foaming, non-flammable hydraulic olls. = 3 Bolt upright press to table. E= Ground machine and test quality of ground, a Prohibit smoking by operator and others near the press. hia Always wear eye protection while operating machine. B= Keep safety latch closed to prevent parts from flying out. E=I Replace parts »nly with Identical parts. E= Matntain a. mechantcal, electrical, and hydraulic parts regularly. amis Never operate at pressures greater than rated pressure. =n inspect hydraulic hoses dally; replace tf damaged. Do not Inspect with hands. ~~ E@A Study Instructlons thoroughly before operating. ABOUT HYDRAULIC SAFETY Hydraulic power Is selected as a driving force for machInery because It Is safe, rellable and efficient. It Is also economical to malntaln and clean to use. There are, however, certain general safety precautions which must be taken when using any hydraulically powered equipment. – Hydraulic ofl In mist form is Ignitable, so smoking and Ignitlon sources must be controlled. – Hydraulic lInes and fittings must be specially selected and rated for thelr required pressure. – Fluld under pressure can escape from cracks or pinholes In fittings ‘ and lines and Is capable of causing Injury or death by Injection Into tissues. Do not feel for leaks while the system 1s under pressure. – Bearings or parts belng pressed can disintegrate and become missiles. Be sure all parts are held stralght and all safety guards are In place. – Leaked hydraulle fluld from poor seals or damaged components can cause hazardous slippery surfaces on concrete floors and dangerous falls. Put absorbe-t material on It and clean up dally. – Hydraulic hoses which are kinked, crushed, or pinched may result In burst lines or components. – Scuffed, cut or damaged hoses are potentially dangerous. Replace them Immediately with hoses of the same specification. – A hydraulle leak ts a danger s!gnal; repair or replace defective parts Immediately. – Wear safety glasses whenever usling hydraulic equipment. – Don’t forget, even when a plece of hydraulic equipment Is stopped, the system may stlll be pressurlzed after the pump Is turned off. Bleed It back before opening for malntenance, – A pressurized system may actuate a machine even when the pump Is turned off, – Treat every machine as a potential hazard: NEVER place hands tn the potnt of operation untill safety blocks are Inserted to prevent closing. – Finally, READ THE INSTRUCTIONS carefully; If you don’t know, don’t guess; ask vour supervisor. 1. INSTALLATION UPRIGHT PRESS Assembly ran A. MOUNTING @ Recommended table hefght 30”. ® Presses can be mounted together on one table or separated by using additional hoses and pipe. eCut hole In table below the shaft changing press. @ Bolt upright press to table. @ Hose connections go from valve to valve In serles (l.e. – pressure hose from pump—?> Inlet of laydown valve outlet of laydown press——Inlet of shaft changing ram outlet of shaft changing ram—+ Inlet of assembly ram outlet of assembly ram valve—+#tank return). WARNING: Air should be bled out of cylinder before using by running rams up and down several Shaft changing. ram timés.

File Type: pdf
File Size: 10 MB
Categories: manuals