Counter EMF… Revisited By Murray Silverman “Counter EMF” (the textbook term), more commonly known in the trade as “back induced voltage” or “generator effect” is an electromagnetic phenome- non present in most all electrical equip- ment and no normally encountered on a direct basis; it does its job without us taking notice. But sometimes it crops up when least expected, and we wind up scratching our heads…what’s going on? A case-in-point. We sold a shop a late model permanent magnet (PM) starter for a Chevrolet S-10 pickup. A diligent mechanic bench tested the unit before installation and complained that the starter was bad…it was hanging up. The starter kept coasting for “several seconds” with the drive extended after power was removed. His concern, and rightly so, was that the starter could stay engaged too long, with possible catastrophic results. We couldn’t reproduce the “defect” in our shop until the mechanic told us that he hooked the “‘S” terminal to the solenoid’s battery stud with a jumper and then applied 12 volts. Sure enough, we got the same results, except that “several seconds” was somewhat over- stated but longer than you might expect! Our friend, back-induced voltage, had reared its normally invisible head as if to say “guess what.” The “guess what” was that the back-induced voltage produced by the still spinning starter was feeding back through the contact disc, (and jumper) keeping the “S” terminal hot and the solenoid engaged until the inertial energy of the armature had dissipated. This affect is not as noticeable on non-PM type starters when similarly connected because some of the back- voltage is dropped across the resistance of the field coils. Deja vu…remember some relay controlled, solenoid actuated Ford starters (Lester 3142) where its solenoid “S” terminal was permanently strapped to the battery stud? It also was slow to release, on the test bench as well as on the car. As far as I know, it was never considered a problem. Here’s an interesting academic exercise for those readers who need convincing: Hook up a rectifier between the motor lead and solenoid with the positive terminal of the rectifier to the starter as in Figure 1. The “ hang-up” goes away because the back-induced voltage is blocked by this added part. Of course this is a solution to a non- problem; on the vehicle things work as you expect. It might be wise to alert customers to these “test-bench” results so they don’t similarly cry “defect.” It should be noted that this particular solenoid for the S-10 starter and many other applications, have a high failure rate. Of 30 tested, seven (23 percent) were defective because of an open hold-in coil ground. Also, if you’re using a Model 300A or equivalent to test solenoids, a separate case ground clip will be required since (surprisingly) the plunger pin is non-metallic and will not pick up a ground when placed on the test fixture. Murray Silverman, is owner of Aztec Technologies.

File Type: pdf
File Size: 887 KB
Categories: eren