Recognizing wave and lap wound armatures COLUMN BY RICHARD R. VENSEL he basic differ- ence between lap and wave wound arma- tures is where the leads are connected to the comm. In wave wound arma- tures (Figure 1), coils are connected in series. They are most popular in autos. Shorts located on top of the lamination are easy to locate on a growler. Figure 1 Figure 2 Commutator In lap wound armatures (Figure 2), coils are connected in parallel. This is used in older armatures and some farm and industrial applications. Internal jumpers are used to interconnect coil groups. Shorts are located on the side of the armature and are almost impossible to find with a growler. Special note: Faults can be found using our armature analyzer. Richard Vensel is owner of Vensel Enterprises, Crystal Lake, Ill. ET RIE!