ERA presents new training video COLUMN WES GRUENINGER SR. AND BOB THOMAS M itsuba’s SM612 and SM710 starters utilize a unique design that presents a challenge for rebuilders. The solenoid in this starter closes motor contacts which are located right on the brush holder. The drive plunger pushes the drive directly without use of a shift lever. This minimizes the number of mov- ing parts and allows for a very compact and lightweight unit. Disassembling one of these starters without damaging salvageable compo- nents is difficult without knowing the proper procedures. The Electrical Rebuilder’s Association (ERA) has produced a training video to on Figure 2—Moveable contact retainer removed. help rebuilders correctly teardown this starter. You can follow along as they com- pletely disassemble the unit into its com- ponent parts including: ¢ Removing the retaining washer from the contact disk shaft. ¢ Removing and testing the suppres- sion diode. ¢ Safely removing the coil lead from the “S” terminal. ¢ Removing the coil from the drive- y ~~ 77 SUPPRESSION end housing. ¢ Removing the starter drive from the shaft assembly. This video is available in the ERA Video Library, located on the ERA Web site (electricalrebuilders.org). It is one of many technical training videos that the ERA has created as part of their mission to help electrical rebuilders deal with both old and new technology. ‘ Figure 4—The coil and starter drive. S) yo Figure 5—Starter drive removed from shaft. Figure 6—Removing brush springs.