TechQO&A remains valuable resource Part IV Alan Melton of Northwest Regular Supply once again lent his moderating skill to the roundtable discussions at the 23rd annual Electrical Rebuilder’s Association (ERA) Trade Show in Nashville, Tenn. The following is a sum- mary of the discussion: Alan Melton [AM]: One of the ques- tions we had is, “What is the difference between the intermittent duty, continuous duty and IMS relays, and are they inter- changeable?” And Bob has volunteered to take that one. Bob Hopko, Iskra [BH]: I’l tell you a little bit about the problems that we’ve had at Iskra. Basically they’re not inter- changeable. And in certain applications, it’s really on an individual basis, and that’s part of the problem out there, is that in certain applications, an IMS relay is a good idea and in other applications it’s not needed. So the answer to the question are they interchangeable is no. On a case- by-case basis, in the Iskra world, absolutely! We’ve had some problems with our new FMS solenoids and I was supposed to come out with a 39MT replacement and they’re not ready to go. And as you guys know being rebuilders, you guys are the experts in this field. You know how it is a case-by-case basis. AM: Intermittent duty solenoids are like a starter solenoid. It’s meant to be used occasionally, short duration, lots of current most likely, but very short dura- tion. A continuous duty solenoid is sup- posed to be able to carry its rated output or rated current forever. So if it’s like a 200- amp continuous duty solenoid it’s designed to carry 200 amps and be latched in continuously, where most of our sole- noids are supposed to latch and unlatch quickly. And an IMS relay—I’m not as familiar with it but I’ll give you my two cents worth—the new solenoids are draw- ing great amounts of current, 50, 75, 100 amps on the switch wire. The IMS sole- noid is saving the ignition switch from that load. So the IMS relay draws about an amp that the ignition switch has to carry and then it carries the high current to pull the switch wire in. Anyone else? BH: Alan’s absolutely right with the IMS relays. The OEMS are really request- ing, can you hear me, are really requesting when they talk to us about having an IMS relay. And you’re going to see probably more on the OE side of these, just to give you a heads up on that. Rebuilder: Alan? Your discussion of continuous versus intermittent, does that mean that you can always use a continu- ous duty, you’re just putting in a more heavy-duty product in place of an inter- mittent duty? And if not, what applica- tions are each one best suited for? AM: Good question. I’ll tell you what, T use continuous duty solenoids in place of isolators where you’re not going to use a battery isolator. There’s applications where isolators just don’t work so you use a continuous duty solenoid there so when you turn the key on, as long as the key is on, the solenoid is latched and carrying current to charge second or your auxiliary battery systems is where I’m most famil- iar with continuous duty solenoids. Dean Conner, Conner’s Repair Service [DC]: I was always taught that the difference between a magnetic switch and a solenoid is the solenoid does physi- cal work, it pulls something. A magnetic switch just makes contact so it draws a lot less current. So in my opinion, a magnetic switch and an IMS switch are the same thing. All it’s doing is making contact. The IMS is mounted right on the starter. And your leads are this long. And you get a lot less draw. We see magnetic switches mounted at the panel with 20 feet of 14- gauge wire running to the starter and you blow fuses. So this is just my take on it and I’m not trying to step on anybody but that’s what I see. AM: That’s a good theory. An inter- mittent or a solenoid is moving something and a continuous duty switch is just clos- ing a relay. DC: It’s closing a relay. So it’s drawing a lot less current. Now I agree with you on the continuous duty. You’re going to turn it on and leave it on as long as the engine’s running. Rebuilder: Recently we had to buy a customer a 29MT IMS switch and we ended up, the guy who was chasing it down ended up going all the way to Delco Remy to find out that you couldn’t sell them—or his recommendation was that you shouldn’t sell him a 39MT IMS switch because they are electrically differ- ent inside. So the reason I guess I’m asking the question is, how product-specific do we have to be when we use this type of product? AM: Just like alternators. If a 29MT’s relay coil is a half-amp coil and the 39MT’s a 2-amp coil you’re going to run into application issues. You’re going to blow a fuse or overload some- thing, and I’m making assumptions but there’s obviously a difference there. And Delco Remy doesn’t spend a penny more than they have to. It took Freightliner 30 years to put a sensing wire on a truck because it cost 20 cents. Rebuilder: Well further information regarding that is that those two relay or two IMS

File Type: pdf
File Size: 4 MB
Categories: eren