Troubleshooting Ford 6G warning lamps COLUMN BY WES GRUENINGER SR. AND BOB THOMAS Y our customer calls: “The alter- nator you sold me is charging, but the battery warning lamp will not go out.” Then he asks why. Fact is, there’s no single answer. The first step toward solving a lamp problem is knowing which Ford charging system you are dealing with and then verifying that both the alternator and the regulator match the application. Once you know for a fact that the correct regu- lator is on the vehicle, you can begin a series of tests that will determine why the charge warning lamp is not going out. Ford charging systems can be divided group of charging systems includes all applications in which the voltage regula- tor controls system voltage. In these vehi- cles the voltage regulator controls both the voltage set point and charge lamp illumination. In some cases, the regulator “T’ terminal is connected directly to the lamp itself. In other vehicles, more typi- cal in later production years, the regulator controls the lamp through the engine control module (ECM) and a micro- processor inside the instrument cluster. The voltage regulators in Table 1 are used in internal voltage controlled alternators. Figure 1— 6G regulator plug codes. OE PART # COLOR TERMINALS F8WU-100359- AB Grey/Grey I-D-A (Fig.1) VP3C3U-10C359-AA Grey/Green DA (Fig. 1) XS7U-10C359-AC | White/White I-FR-A (Fig.2) XS7U-10C359-AC White/Orange | I-FR-A_ (Fig.2) VP4L1U-10C359-AA | Black/Black I-FR-A_ (Fig.2) Table 1— Internal voltage control regulators. into two groups: those with internal volt- age control and those with external volt- age control. You have to identify which type you are working with, because they are as different as apples and oranges, and each must be tested differently. Internal voltage control Usually found on V-8 engines, this All of these regulators and charging circuits have two things in common. They all use the “A” terminal as a voltage sense point, and they all use the ‘T’ ter- minal for excitation and warning lamp control. The grey regulators do not use the center terminal. The “D” stands for dummy. The white regulators in this group use the center terminal to send a field duty cycle signal to the ECM. The FR terminal (field rate monitor) is an out- put terminal and has nothing to do with actual regulator operation. It is used by the ECM to monitor the field duty cycle, which is directly proportional to the mechanical load that the alternator is plac- ing on the engine (Figures 3 and 5). In early applications, the charge lamp is connected directly to the regulator “T’ terminal (Figures 2 and 3). Voltage passes through the lamp to turn on the regulator. Once the alternator begins charging nor- mally, a driver inside the regulator turns the lamp off by removing the ground from the lamp circuit. These conventional lamp circuits seldom cause false warning lamp problems. When they do, you can check it fairly easily. If the lamp goes out when you unplug the regulator, then the prob- lem is inside the alternator. However, in later applications, the “T’ terminal is connected to the ECM (Figures 4 and 5) or directly to a microprocessor in the instrument cluster (Figure 6), which turns on the regulator by applying low voltage. If you read the voltage on an unplugged “T”’ terminal wire with the key on, you can read this low voltage signal. This is called an open circuit reading because voltage is present—but the cir- cuit is incomplete until it is plugged in. If you plug the connector into the regulator, the voltage at the “I” terminal will drop. This is often referred to as pull-down voltage. Once the alternator begins to charge normally, the regulator changes the pull-down voltage. That change of pull-down voltage is what tells the ECM that the charging system is working nor- mally. The ECM will then send that infor- mation over the vehicle’s data network to the microprocessor inside of the instru- ment cluster. The charge warning lamp then should be turned off by the instru- ment cluster processor. If the pull-down voltage is more or less than what is expected, the ECM may not send the OK message, even though sys- tem voltage shows that the alternator is charging. If the OK message is not sent, the instrument cluster will not turn off the lamp. It is worth mentioning here that the ECM also monitors system voltage. If at any time the voltage is too high or too low, it will set a fault code and send a message to the instrument cluster that there is a problem with the charging sys- tem. As you can see, there is a lot that can go wrong here to cause the lamp to stay on—even if the alternator is charging normally. If everything seems to be charging correctly, but the lamp will not go out, per- form this simple test with the engine off: Unplug the alternator. Using a digital multimeter, measure the resistance between the regulator “I” terminal and ground (Figure 7). On some applications, you may be able do this on the vehicle w

File Type: pdf
File Size: 4 MB
Categories: eren