a ERU FILE IN FHE af 6 prestolite SERVICE MANUAL SMALL MOTOR SECTION (Issued 3-16-78) These series type motors are reversible and are designed for electrical transmission shifts. VOLTS 12 ROTATION BEARINGS LUBRICATION END PLAY – TEST SPECIFICATIONS ° . Free :Running . _ Load Test.at 5..0.Ft. On. . ‘Stall Test Reversible BRUSHES) 2 POLES 2° Absorbent bronze bearings. ‘ Bronze bearings are lubricated at assembly and do not require periodic lubrication. Deo not clean bearings with grease solvent 2s it would wash all lubrication from the _felta, At overhaul,. soak felts in medium. engine c cil and, eons coat ‘bearings with a light grease. – Separate. Le See Tabulation. Refer to Parts & Equipment List for thrust washer package. ‘ Test in both directions of: rotation : 12.0 volts, _ 8.0 maximum vamperes 12.0 volts, 35.0 maximum amperes, 1400 minimuny “RPM. 12.0 volts, 43.0 maximum amperes, 9.6 minimum Ft. Oz. Unit – End Play __-Special Instructions ERU-4001- .0o5″-. 018″ © ‘Note 1 ERU-4002 . ..005″-.018″ Note 1 ERU-4003 . O05″. 025″ Note 1 NOTE 1 – Motor frame must be grounded. For CWDE rotation, connect red lead to battery. For CCWDE rotation, connect black lead to battery. BLACK RED oo —_——— ll ee Printed in US. A.