ERA Office: Monday – Friday 9:00-5:00 CST

275 W. BROWN ST, UNION, MO 63084

636-584-7400

office@electricalrebuilders.org

ERA Tech Helpline: 636-584-TECH (8324)

Pressure Test Your Oil Seals BY NATHAN UNGER Geren a customer will bring in a “wet-clutch” starter that is completely soaked with oil throughout, including the solenoid. What caused that? Did the seals fail? Were the seals defective to begin with? Apparently they are not designed for more than about 7.5 psi. It occasionally happens that the vent on the machine’s oil reservoir is plugged, and thus the internal pressure can exceed what the starter seals are designed for. Sometimes the mechanic has overfilled the reservoir. I always make a point of advising the customer if I suspect this. But I want to be able to verify the seals before my rebuilt starter goes out of my shop. Also, this would make it easier to negotiate any warranty considerations. So I went down to the local Home Depot, picked up some plumbing supplies and made myself a pressure tester. To Make It: First of all, I cut the flange off of a 42MT drive end housing. On the lathe, I bored it out so that it would fit over the top of the drive end housing of the customer’s wet-clutch starter, whether it is a 40MT, 42MT, 50MT, Japanese make, or other type. Many of them have a similar mounting style. For the 1OMT size I made an adaptor flange. I fitted and sealed the plumbing parts to the flange, making sure that it would clear the nose of the starter. Next, I mounted a pressure-release valve (PRV). I took the PRV apart and shortened the spring inside so that the valve would release at less than 10 psi. I also mounted a low-pressure gauge and a small ball valve with a t-handle. After that, I mounted the pressure regulator that I set to about 5 psi, and I finally added a male air hose coupler. Now I needed a gasket to seal the flange to a starter. A 25SI rubber gasket cut to the right shape worked just fine. Next, I bought some “EZ Lok” inserts suitable for % – 13 bolts and installed them with thread-locking compound into the mounting holes of the flange. That way I could just bolt the starters right onto the pressure tester without needing backing nuts. To Use It: Connect the air hose, and let the pressure equalize. The combined use of the pressure regulator and the pressure- release valve should eliminate any chance of over-pressure. Then close the valve to prevent any more air from coming in. I always tap the gauge, because it always seems to need to settle a bit before I can take a reading. I watch the gauge to see if the pressure drops. If it does not drop, then ‘m home free. If it does drop, then I get out a spray bottle of leak detection fluid to help look for bubbles, and mark the leaking areas for later servicing. Then I remove the air hose, open the valve to release the pressure, and unbolt the tester. If you decide to make one, too, have fun, and let me know if you come up with any improvements. Nathan Unger is the owner of ASI Rebuilders, Abbotsford, British Columbia, Canada. TET RIA] Components of the pressure tester 50MT STARTER THREAD INSERT BELL FITTINGS AND FLANGE MOUNTING ASSEMBLY PRESSURE RELEASE VALVE SET TO UNDER 10 PSI PRESSURE GAUGE SMALL BALL VALVE PRESSURE REGULATOR SETTO 5 PSI AIR COUPLER Page 1

File Type: pdf
File Size: 1 MB
Categories: eren