ELECTRICAL REBUILDER’S ASSOCIATION—Technical Document S$S201405B www.electricalrebuilders.org Vented Solenoids Where and why? BY BOB THOMAS Dw introduced their first permanent magnet starters in 1987 with a new, much smaller solenoid. Most rebuilders will remember that this solenoid was pressed in and secured to the DE (drive end) housing using a stamping process. Delco listed a single part number for both the DE housing and the solenoid in their parts breakdown. Of course it did not take rebuilders long to figure out how to drill the housing to remove the solenoid and salvage the housing. Replacement solenoids were supplied by aftermarket companies with tapped holes and mounting bolts (see Figure 1). When the PG260M starter appeared ten years later, the new solenoid used was similar in size, but the mounting was changed to a more conventional arrangement using three 4mm _torx- head machine screws. As the PG260M was followed by, what seems like, countless other PG260 variations with non-interchangeable internal parts, the solenoid remained pretty much the same, except for some marine and industrial applications that required an Figure 1—Delco’s first PMGR starter had a staked-in-place solenoid. This starter sports an aftermarket solenoid held in place by screws. “R” terminal (see Figure 2). This held true until 1999, when Delco added a solenoid cap vent to some General Motors applications (see Figures 3 and 4). As you can see, the vent hole is covered with a wire screen which is loosely shielded by a plastic cover. Unfortunately, there was never any official announcement on the purpose of this vent—it just appeared. Consensus in the aftermarket seems to point to some problems with moisture being trapped inside the cap, freezing in cold weather and preventing the solenoid contacts from closing properly. The vent, theoretically, allowed moisture to escape from the cap when the engine heated the starter during driving. Even a parked vehicle would be warm enough to drive any moisture out of the vent before it cooled down. You may be wondering how a crimped and sealed solenoid cap could collect moisture in the first place. A difference in air pressure can be a powerful force. Engine temperatures well above 225 °F transfer to all of the accessories, including the starter and the solenoid. Proximity to an exhaust manifold, heated to over 1,000 °F can cause some solenoids to become even hotter than the engine block. As the air inside the solenoid cap is heated, it expands. This creates pressure inside the solenoid cap and forces some of the air to escape around the cap’s gasket. When the vehicle is parked, and everything cools down, the air pressure inside the cap drops dramatically, creating a partial vacuum. This is when the outside air is pulled back into the cap. If the drawn-in air happens to be laden with moisture, water is introduced into the solenoid. If the temperature continues to drop, as it might when a strong cold front passes Figure 2—PG260 solenoids, with R terminal (left) and without R terminal (right). An ERA Publication. ©2014, Electrical Rebuilder’s Association. All rights reserved. No portion of the guide may be reproduced in any way, or stored in any electronic retrieval system without the prior written consent of the Electrical Rebuilder’s Association. Page 1

File Type: pdf
File Size: 2 MB
Categories: eren