ELECTRICAL REBUILDER’S ASSOCIATION—Technical Document $S201406C www.electricalrebuilders.org Rebuilding Tip: Nissan Forklift Starter Hitachi $ 114-482 BY BOB THOMAS e sella few forklift starters now and again, but one particular part number has been a real problem for customers—specifically, Hitachi $114- 482 (Lester 18054). This starter was used on Nissan, TCM and CAT forklifts, at least 14 different models that we are aware of. The problem is caused by two factors that combine to create a no-crank condition or a weak engagement. These conditions have damaged ignition switches from excessive loads and have damaged pinion gears or flywheel ring gears from weak engagement. The first customer that came to us with this problem had eight of these lifts, and he told me that the starters they had been buying lasted only a few months. Many of them that he brought to me for rebuilding, worked on the bench, and other than some milling on the pinion, they seemed to be in good condition. The symptoms that he described were poor drive engagement, an audible “click” but no crank, or sometimes no response at all when the ignition switch was turned to start. Part of the problem is the high current draw of the pull-in and hold- in coils on Hitachi starters. The other is that these lifts came from the factory without a starter relay to handle that excessive load. Obviously the switch and the wiring were sufficient when everything was new. But as the lift trucks aged, cranking problems developed. In addition, we have found that many aftermarket solenoids actually require more amperage on pull-in than the original solenoids that Hitachi manufactured. This happens because the aftermarket often changes the wire size and turn count in a solenoid to keep the cost down. CAT published a technical service bulletin in 2008 describing the problem. Their fix was a starter relay kit with the CAT part number SE000146. Our solution was to mount an auxiliary starting relay on every one of these starters, after checking with the customer about possible clearance issues. As shown and described below, we used a Bosch relay that is rated at 50 amps continuous duty. This relay can easily handle the intermittent load of the solenoid coils, which can be as high as 60 amps with an aftermarket solenoid. I also supply each customer with a copy of the CAT TSB, which can be found in the ERA Technical Library. When a customer who has been using these lifts, sees a list of the very symptoms that they have been experiencing, printed on a factory service bulletin, it gets their attention. Special thanks to Jim Talsma, Adema Alternator & Starter Service in Coopersville, MI for helping us to solve this problem and for supplying the CAT technical service bulletin. Figure 1—We used a #21 drill bit to create a hole 9mm deep on the side of the DE (drive end) housing at the location shown. We cut 10-32 threads in the hole with a tap and attached a 50A Bosch relay, part number 0-332-019-110, to the starter. The 10-32 mounting bolt also served as a ground connection for relay terminal 85. BATTERY ®080000 +8 STARTER Figure 2—We used 12 AWG wire to connect the B+ and switch terminals on the starter to the relay as shown. B+ is connected to terminal 30 on the relay and the solenoid-switch wire is connected to terminal 87 on the relay. We then attached the original solenoid-switch harness connector to the number 86 relay terminal. IGNITION SWITCH SINGLE-POLE SINGLE-THROW RELAY Figure 3—This diagram shows how the relay is connected to the starter solenoid and to the original forklift wires. It is taken from the article Solving Problems Using Relays – Or – Four Handy Uses for Bosch Relays by Wes Grueninger Sr. and Bob Thomas. An ERA Publication. ©2014, Electrical Rebuilder’s Association. All rights reserved. No portion of the guide may be reproduced in any way, or stored in any electronic retrieval system without the prior written consent of the Electrical Rebuilder’s Association. Page 1
File Type:
pdf
File Size:
1 MB
Categories:
eren