ELECTRICAL REBUILDER’S ASSOCIATION—Technical Document $S201407B www.electricalrebuilders.org Rebuilding Tip Solenoid substitution on 35MT starter with exposed shift lever BY BOB THOMAS f you should find yourself rebuilding a 30MT or 35MT starter with an exposed shift lever, such as this Delco 1113619 (see Figure 1), you will quickly realize that most of the parts are NLA (no longer available). This particular starter came from a customer working on a 1958 Detroit Diesel engine on a stationary generator. It was in pretty good condition given its age, except for worn out brushes, a drive end bushing that was almost non- existent and a badly damaged solenoid. Both the battery stud and the motor stud on the solenoid were stripped, and the insulators and wires under the cap were broken. This was not a restoration project. The stationary generator was being used as an emergency backup for a local county’ vehicle maintenance facility. Therefore, I decided to look for an alternative solenoid that might work in place of the original. Delco D985, better known by the Accurate part number 951, looked like it could work. The D985 fit later model 30MT and 35MT starters. It has a slightly larger bore, but it looked similar enough to work. The plunger throw was also similar, and was adjustable, using the external linkage. The plunger shaft on these older starters is threaded and screws into threads in the end of the plunger. A tang in the original solenoid’s bore fits into a slot in the plunger to prevent it from rotating on the threads, once it is in place. So the first concern was preventing the plunger from rotating, once it was adjusted. I used thread-locking compound for that. The next problem to solve was the taper on the contact side of the original plunger, which was shallower than the plunger normally used with a D985 solenoid (see Figure 2). This meant that the plunger would bottom out before closing the contacts. The solution required a visit to a machine shop, where the taper on the original plunger was cut to match the taper on a D985 plunger (see Figure 3). Pinion clearance on these old starters can be adjusted using the slotted mounting holes in the solenoid or by rotating the plunger on the threaded plunger shaft. The pinion clearance specification of 23/64”, plus or minus 1/32”, roughly works out to .360”, plus or minus .030”. Once the solenoid was mounted, there was plenty of thread on the original plunger and shaft to achieve proper pinion clearance. Then a medium strength wicking-style locking compound was applied to the threads to prevent the plunger from turning. Thanks to Art Glass, Willard Generator Service, Bridgeville, PA for sharing his experience and Delco-Remy Service Bulletin 1M-120. Figure 1—Early-style 35MT starter with external shift lever, shown with late-style D985 solenoid attached. Figure 2—Late-style plunger with rod attached is next to original plunger without a rod (left). Note the original early-style plunger has a taper that is much more blunt. Figure 3—After being recut, the taper on the original plunger (left) is nearly identical. An ERA Publication. ©2014, Electrical Rebuilder’s Association. All rights reserved. No portion of the guide may be reproduced in any way, or stored in any electronic retrieval system without the prior written consent of the Electrical Rebuilder’s Association. Page 1
File Type:
pdf
File Size:
1 MB
Categories:
eren