Originally published October, 2014, in THE EXCHANGE – a publication of the Electrical Rebuilder’s Association www.electricalrebuilders.org “The Usual Suspects” Blaming voltage regulators BY BOB THOMAS “T! must be a bad _ voltage regulator.” How I wish I had a dollar for every time I heard those seven words. Since they were invented, voltage regulators have been taking most of the blame for charging system malfunctions. Guilty or not, they have often been replaced and discarded. Sometimes, when that failed to correct the problem, they have even been replaced again. I have had customers specifically request that I replace their voltage regulator, because a friend, relative or neighbor told them that it was causing all of their electrical troubles. I have also heard that the parts store has tested “this” alternator and proclaimed that it definitely had a bad regulator. How could anyone possibly know that? Overcharging, undercharging or not charging at all—there are always other things that could cause those malfunctions besides the voltage regulator. Yet, definitively, the parts store employee standing next to a computerized test bench or the neighbor who has been “fixing” cars since he was in high school, announces that the voltage regulator is bad. How can anyone argue against that? Not long ago, I talked to someone who said that he had replaced a regula- tor three times, and the alternator was still not working. When I asked him why he kept changing the regulator, he told me “Every other part tested good” When I asked if he tested the voltage regulator, he said “No”. When I asked why, he said, “T figured it had to be a bad regulator, because everything else tested good.” Did “everything else” include the ground and B+ connec- fixed” than be bothered with testing the system. But at the same time, I installed only a handful of those replacements myself, because the original mechani- cal regulators were so reliable. Overall, most voltage regulators today are pretty reliable, too. So why are so many of them considered the “usual suspect” when an alternator fails to work properly? I believe that it has to do with tions to the regulator, the input to regula- tor plug or the rotor field draw? I admit that some voltage regulators were unreliable when they were first introduced in the market—Lucas comes to mind. Everybody makes mistakes. But those were the exceptions, and in most cases, problems were detected and eventually corrected. Lucas did take their time with that, but their final electronic regulators were nearly bulletproof. Denso was one of the last electrical manufacturers to abandon mechanical voltage regulators and switch to elec- tronic regulators in the 1980s. I sold hundreds of electronic replacement reg- ulators to garage customers who would rather sell two parts (alternator and regulator) “to be sure that the car was a misun- derstanding of what the regulator ac- tually does, and in some cases, the belief that “new is al- ways better.” All voltage regulators do basically the same thing. They switch the field circuit on and off many times a second while monitoring the voltage output of the alternator. By controlling the “on” time, they can con- trol the output voltage. Some regulators control the negative or ground side of the field circuit and are referred to as A-circuit. The others control the posi- tive side of the field and are referred to as B-circuit. There are different ways that regulators can be turned on (or be “excited”) to charge, and there are many different plug configurations. But basi- cally, all regulators turn on the field cir- cuit when excited, and once they turn it on,they switch it off-and-on to control the voltage. If an alternator overcharges or undercharges, it does not necessarily mean that the regulator is at fault. Voltage regulators depend upon good connections to B+ and B- for a reference point. Different regulators require different forms of excitation, be it voltage through an indicator lamp, battery voltage from the ignition circuit or a low voltage signal from an electronic device like an engine control module. Sometimes, that signal may even request different voltage set points, or be delayed for a specific length of time after engine-start. I typically test all voltage regulators, even if I plan to replace them (the same as I test all rectifiers.) I connect each one to the regulator tester, using connections that match the application, and allow each one to do exactly what it was built to do—regulate voltage. I let it run on the tester for minutes, not seconds. If I plan to reuse it, I often let it run on the tester while I do other things. You can run a voltage regulator on a tester for hours, if that is what it takes to convince you that the “usual suspect” is, in fact, innocent of any malfunction. Many years ago a good friend who manufactured and sold voltage regulators told me that the most reliable voltage regulator was the one that had been tested inside an

File Type: pdf
File Size: 2 MB
Categories: eren