ELECTRICAL REBUILDER’S ASSOCIATION—Technical Document CS201501A wwweelectricalrebuilders.org 1938 Buick—Delco Voltage Regulator Think outside the box BY BOB THOMAS hen a customer called to inquire about rebuilding the generator on a 1938 Buick, I instructed him to bring in both the generator and the voltage regulator. “They operate as a team,’ I told him. “T insist that we test them that way.’ According to the number on the generator’s original tag (see Figures 1 and 2), this was probably the original generator that came on the Buick from the factory, although it obviously had been rebuilt an unknown number of times. It failed a motor test and did not produce voltage on its own when spun. It had new brushes, but the commutator had already been turned one too many times. The armature failed a short-to- ground test and had slung solder to boot. I sent it out to be rewound and have a new commutator installed. The regulator was the two-unit type and was mostly original. I tested it using a known-to-be functional 6-volt Bosch VW generator that I often use to check 6-volt A-circuit regulators. The regulator failed to let the generator charge, and adjusting spring tension proved futile (see Figure 3). A close inspection of the control relay contacts revealed the reason why. They were melted together, and the upper contact was detached from the stationary arm. After bending the stationary arm out of the way, it was easier to view what had happened (see Figure 4). 1 considered the options: repair this regulator or find something to replace it. My customer (who was not the owner of the vehicle) told me that the “old man” who owned the car just liked to drive it around the block and did not care what regulator we used—as long as it kept his battery up. Of course, there are still quite a few 6-volt, negative ground, A-circuit regu- lators being manufactured today, but none of them “look” the same or have the same mounting base. A search on- line showed that there were NOS (new old stock) regulators for sale that were very similar with the same configura- tion, but all were priced at over $100 and were being offered as “no return”. This regulator had the Delco part num- ber that matched with this generator number. I did not want to replace it un- less I had no other choice. I tried “think- ing outside the box’, considering what I knew. The cutout relay was functioning. This generator was the three-brush type, so amperage was somewhat limited by voltage output of the third brush (see Figure 5). Third-brush output always drops off as armature speed increases. This drop is caused by a distortion of the magnetic field between the generator’s poles as a result of magnetism within the spinning armature laminations. The amount of distortion increases with the rpm and amperage being produced in the armature. Any increase in speed or increase in armature output will increase the distortion and consequently ANOERSON INI 1101052 8 U2 7 6 y MADEIN U.S.) A a TRC A EOS Figure 2—A close look at the generator’s original identification tag. decrease third-brush output. As a result, the amperage-limiting ability of the original control relay was not absolutely crucial in this application. A more detailed explanation of this phenomenon may be found in the article “Early Forms of Generator Regulation’, which is archived on the Figure 3—The cutout relay is on the left, the control relay is on the right. ERA website. Anelectronic 6-volt, negative ground, A-circuit regulator that would fit inside the original cover, could replace the bad relay. I thought that a 10SI regulator should work (using only the three tab connections). Those mounting-bolt connections are positive, negative and An ERA Publication. ©2014, Electrical Rebuilder’s Association. All rights reserved. No portion of the guide may be reproduced in any way, or stored in any electronic retrieval system without the prior written consent of the Electrical Rebuilder’s Association. Page 1
File Type:
pdf
File Size:
4 MB
Categories:
eren