CHARGING SYSTEM CIRCUITS AND REGULATOR SERVICING DELCO-REMY PASSENGER CAR TYPE REGULATORS CLEANING CONTACT POINTS % ) If points are oxidized or dirty but not badly burned or pitted they should be cleaned. To clean regulator points properly, it will usually be necessary to tilt to one side or completely remove the upper point support. The large flat contact used on current regulators and on single contact voltage regulators should be cleaned with a spoon or riffler file. It is not necessary to have a flat surface on this contact point. However all oxides should be removed so that pure metal is exposed. The small soft contact points on single contact voltage regulators, current regu- lators, double contact voltage regulators and the contacts of cutout relays should be cleaned with crocus cloth or flexible abrasive material. After contacts have been cleaned, they should be washed with clear carbon tetrachloride to remove any foreign material. NOTE: -NEVER USE EMERY CLOTH OR SANDPAPER TO CLEAN CONTACT POINTS. Regulator Parts Replacement: Voltage or Current Regulator upper contact support brackets can be replaced. The replacement of armatures usually requires that holes be drilled. To perform this operation it is imperative that the manufacturers service instructions be very carefully followed. > CUTOUT RELAY ADJUSTMENTS Air gap: Place fingers on armature directly above core and move armature down until points just close. Then measure air gap between armature and center of core. Make sure that all points close simultaneously. If they do not, bend spring fingers so they do. To adjust air gap, loosen two screws at back of relay and raise or lower the armature as required. Point opening: Check point opening and adjust by bending upper armature stop. Closing voltage adjustment: Adjust closing voltage by turning adjusting screw. Turn screw clockwise to increase closing voltage and counter-clockwise to decrease voltage setting. CURRENT REGULATOR ADJUSTMENTS Air gap: Push armature down until contact points are just touching. Measure air gap between armature and winding core. Adjust by: loosening two contact bracket mounting screws on front of unit and with proper size thickness gauge inserted between armature and winding core, raise or lower bracket as required, Check point alignment. Current setting adjustment: To adjust current setting, turn adjusting screw on back of unit to increase or decrease spring tension on the armature. Turn clock- aS Wise to increase current setting and counter-clockwise to decrease setting. Final setting should be approached by increasing spring tension. ES ee ot ee 9 VOLTAGE REGULATOR ADJUSTMENTS SINGLE CONTACT TYPE Air gap: To check air gap, push armature down (do not apply pressure to contact strip) until the contact points are just touching, and then measure the air gap between the arrnature and the center of the core. Adjust by loosening the contact mounting screws and raising or lowering the contact bracket as required. Be sure the points are properly aligned when tightening screws. Voltage setting adjustment: To adjust voltage setting, turn adjusting screw. Turn screw clockwise to increase voltage setting and counter-clockwise to decrease voltage setting. CAUTION: If adjusting screw is turned down (clockwise) beyond the normal adjustment range, spring support may fail to return when pressure is relieved. In such case, turn screw counter-clockwise until sufficient clearance develops between the screw head and spring support, then bend spring support upward carefully with a small pliers until contact is made with screw head, Final setting of the unit should always be approached by increasing the spring tension, never by reducing it, If setting is too high, adjust until below required value,and then raise to exact setting by increasing spring tension. DOUBLE CONTACT TYPE Air gap: Turn air gap adjusting screw on top of armature all the way (in clock- wise direction) befote checking air gap. To check air gap place fingers on armature above winding core (not on bi-metal strip) and push armature down until upper contact points are just touching, then measure air gap between armature and center of core. Adjust by placing proper size thickness gauge between armature and winding core, press armature down for firm contact, and bend upper contact support to a “point touching” position, Check for proper point alignment. Point opening: Push armature down (avoid bi-metal strip) until LOWER set of contact points are just touching and measure point opening between UPPER set of contacts. Adjust to proper clearance by bending LOWER contact support. Voltage setting adjustment: To adjust voltage setting (lower contact operation) turn double slotted screw on back of unit to increase or decrease spring tension on the armature. Clockwise for higher voltage setting, counter-clockwise for lower voltage setting. Differential voltage may be (upper contacts) adjusted by turning air gap adjusting screw, on top of armature clockwise to increase differ- ential voltage, counter-clockwise to decrease differential voltage. This screw should not be moved more than 3/4 turn counter-clockwise from the maximum clockwise position,

File Type: pdf
File Size: 9 MB
Categories: techlib