oâ„¢ GHG FILE IN THE @, Prestosuize SERVICE MANUAL y= GENERATOR SECTION , (Issued 3-16-78} VOLTS 24 RATED OUTPUT 10 Amperes VENTILATED Yes ROTATION See Tabulation BRUSHES 2 POLES 2 CONTROL Vibrating Current-Voltage Regulator GROUND POLARITY See Tabulation BEARINGS Ball atdrive end. Absorhben bronze at commutator end. LUBRICATION . ‘Periodically add 5 drops of medium engine oil to end head Oilers. At cverhaul, pack open bal] bearings 1/4 to t/2 full with a good ball bearing lubricant. NOTE – Some ball bearings are sealed, these units ara prelubricated and re- quire no additional lubrication. BRUSH SPRING TENSION 18 to 36 ounces with new brushes. Brush spring tension is i ae ‘ measured by using an adaptor and hooking it under the brus arm as near to the brush as possible. Take the reading ju: as the arm leaves the brush. , FIELD COIL DRAW (70°F.) .78 to .83 amperes at 20.0 volts. MOTOR DRAW (70°F.) 1.9 to 2.6 amperes at 20.0 volts. (Have field terminal grounded to frame.) OUTPUT TESTS (70°F.) 28.0 volts, 4.0 amperes at 1140 maximum RPRI. 30.0 volts, 10.0 amperes at 1500 maximum RPM. Ground Special _ pi Rotation _Polarity Internal Wiring __instructions GUG-GHOL A CWDE Negative Figure | i GHG-SQOLAT. BT CWDE Positive Figure | Note | GHG-8001C.D CWDE Positive Figure | GHGO-6001CT CWDE Negative Figure 1 Note | GHG-6002Aa T CCWDE Negative Figure 2 Note } GHG-TOOLA.B CWDE Positive Figure f NOTE 1 – After inspection of the various parts, paint terminal stud and brush holder insulation with red glyptol. Cover glyptol and all metal surfaces except pilots, head seats, threads, commutator and bearing surfaces with an air- drying, fungus-resistant varnish. Allow varnish to soak into field coils and armature windings. Drain and dry thoroughly before assembling generator. Page 2 Si prestolite SERNIce MANUAL GHG continued FIELO ARMATURE TERMINAL, GROUNDED BRUSH INSULATED BRUSH VIEWED FROM COMMUTATOR END Figure 1 Priavdia ON A ARMATURE TERMINAL, INSULATED BRUSH GROUNDED BRUSH VIEWED FROM COMMUTATOR END Figure 2