HUPMOBILE MODEL E-2 (1925-26) AUTO-LITE GENERATING, STARTING AND LIGHTING SYSTEM AUTO-LITE IGNITION BATTERY.—Willard, Type SJR-6. 6 volt. 155 ampere hour. Starting capacity is 165 amperes for 20 minutes. Lighting capacity is 5 amperes for 31 hours. The positive (++) terminal is grounded. (rs) IGNITION.—Coil Model 2182. Distributor Model 5295. Breaker contacts separate .0225- ba 0275 inch. Resurface contacts with a fine, flat jeweler’s file or on a medium hard oilstone. Breaker uses double contacts with a four-sided cam, contact arms being set at an angle of 45° and opening alternately. Distributor is of the semi-automatic HORN type. Manual advance is 38°, Automatic advance begins at 1600 R.P.M. and reaches a maximum of 21-26° at 3600 R.P.M. The tension of the breaker arm spring is 16-20 ounces. Oiling.—Put 8 or 10 drops of light engine oil in the oiler on the side of the distributor & housing every two weeks or each 500 miles. Wipe out the distributor head with heavy grease, removing all excess and polishing with a soft clean cloth every 5000 @) miles. Put a small bit of heavy grease on the face of the breaker cam under the | fiber bumper of the contact arm every 1000 miles. 2 Timing.—Breaker contacts begin to separate when No. 8 piston on compression stroke i? (with both valves closed) reaches top dead center with the manual spark control Sntian coal lever in the half advanced position or midway between the fully retarded and fully —_——— advanced position. Re a aue Firing Order.—The firing order is 1-5-2-3-8-4-7-6. | Voc Spark Plugs.—Spark plug diameters are 7% inch. Gaps are .022-.025 inch. a fae Ba STARTER.—Medel MR-4101. Starter is connected to the engine through a Bendix drive. The direction of rotation is counter-clockwise, looking at the commutator end. Starter cranks the engine at 140 R.P.M. drawing 100 amperes at 6 volts. Starter brush tension should be 114-114 pounds each. Starter switch is Model SW-4001. rnicdacarsd Starter Data @ Torque R.P.M. Volts Amperes ae O} [Bev ftcseeeercce se Pree jcc see 59) cee sank 60 (Without Bendix) 7 iy necccucsnseaveereons Free -……ccecceeeee Fh « nn Salk Cen 70 (With Bendix) Po eee D2 D5 casi es, 57. a ENS 100 LIGHTING AND Ged) wreeietee ese Queene aes iAP eo 200 IGNITION SWITCH | 2) eT cs) | ene Pe en SO: 300 TOS R eecsscssresceese 300 cence Cfo ee, 400 av en enero. Loockias:=s.e2 se ye reese orem 820 Mounting.—Starter is barrel mounted at rear of flywheel housing at right of engine. fo remove starter, remove large taper pointed pilot cap screw and locknut. Then slide starter from place. sicnat swine, «= DASH LAMP switcu Oiling.—Starter bearings are of the oilless type. They require no attention. GENERATOR.—Model GXB-4101. The direction of rotation is coynter-clockwise, look- ing at the commutator end. Generator current regulation is by the third brush sys- tem. To adjust the generator output, remove the commutator cover band and shift the third brush mounting plate by tapping on the third brush mounting stud with a screw driver. Moving the third beak in a counter-clockwise direction increases the charging rate and in the opposite direction decreases the charging rate. The mounting plate is held in any desired position by friction between the third brush rei gee stud and the generator end plate. Maximum charging rate is 17 amperes at © volts. TAR LIGHT (Gu Gs 4 HUPMOBILE MODEL E-2 (1925-26) AUTO-LITE GENERATING, STARTING AND LIGHTING SYSTEM DELCO IGNITION Generator Data Cold Test Hot Test Amperes_ Volts R.P.M. M.P.H. Amperes Volts R.P.M. M.P.H. Dessserernens 6.6… .cseeee 550….sesseee 9.7 Di nsntererss | an 620… B ccccwhs ‘waa: G00; 11.4 | ae: 700………..- 10… ty fs eee {NE 13.1 s(t eee Y 6 Emenee 900… ;,.< 15.9 i ’ }/ [aa 1200............ 21.2 14.0... 8.2.00 1600 Motoring freely generator draws 5.3 amperes at 6 volts. Shunt field draws 2.5 amperes at 6.2 volts. Generator brush tension is 114-1! pounds each. Mounting.—Generator is flange mounted at right of engine. Slotted holes are pro- vided for the three mounting screws. Adjustment of the drive chain tension is made by shifting the generator in position. Tighten the set screw in the lower mounting slot to retain position after adjusting generator. The chain must not be too tight or it will crowd the generator bearings causing wear. Oiling—Put 4 or 5 drops of light engine oil in the oiler on the commutator end of the generator every two weeks or each 500 miles. The drive end bearing is oiled by splash from the gear case. RELAY.—Model CB-4009. Relay is mounted on top of the generator. Relay contacts close when the voltage of the generator reaches 7-7.5 volts and open with a dis- charge current of .5-2.5 amperes. Contacts separate .025-.035 inch. Air gap be- tween relay armature and coil core is .010-.030 inch. contacts closed. LIGHTING.—Head and stop lamps are each 6-8 volt, 21 cp. S. C. Dash, dome, side and tail lamps are each 6-8 volt, 2 cp. S. C. FUSES.—Generator field fuse is 5 amperes. Ligh