Avalanche Diode Tester IPM No. 0T-0056 ‘ INTRODUCTION Diodes being used in some of the new alternators are a special type. These special diodes are being used to help protect the electrical system from high voltage. These diodes are called transient suppressors or avalanche diodes. The diodes are also of the passivated die (chip) types; passivated means that the chip is sealed or protected and does not require a can or plastic moulded case. These diodes are, however, covered with silicon rubber in the alternator bridge assembly to prevent gross shorts caused by water and dirt. This tester is designed to test the normal rectification function of the diodes. In addition, the OT-0056 enables you to test the avalanche function and to determine the voltage at which the avalanche occurs. FUNCTION TEST Approximately 20 Volts AC peak is to be applied to the diodes during this test. The voltage is adjusted in the “AC Volts” position of the selector switch. The voltage is adjusted by turning the knob marked “Volts Adjustment” until the meter reads 20. LEAKAGE TEST Approximately 20 Volts DC is to be appled to, the diodes during this test. The voltage is adjusted in the “DC Volts” position of the selector switch. This is accomplished by turing the knob marked “Volts sis namie until the meter reads 20. AVALANCHE VOLTAGE TEST The meter is used to indicate a rapid increase of diode leakage. The DC voltage is increased until the leakage has been observed. The voltage is read by switching back to the “DC Volts” position of the selector switch. OPERATION FUNCTION TEST . Attach three test leads to the front of the tester. . Plug tester into 115 VAC outlet; grounded 3 wire outlets should be used. Turn Volts adjustment C.C.W. (to zero output). . Turn selector switch to AC Volts positon. Turn power switch to on. Attach red lead to the positive heat sink. . Attach black test lead to the negative heat sink. . Attach the yellow test lead to the junction of one pair of positive and negative diodes. , . Adjust the Volts Adjustment to read 20 on the meter (the two L.E.D. lights marked “Open” will be lit when the tester is on and the voltage tuned up. Disregard them except when testing with the selector switch in the “Function Test” position). 10. Switch to Function Test – all L.E.D. lights should be out – if any are lit then they are showing you the failure mode of the diodes., i.e. open or short. 11. Move-the yellow lead to the next diode pair until each pair is tested. ! ! LEAKAGE TEST: 1. After performing the function test be sure the selector switch is turned to the DC Volts position. ~~” . The volts adjustment is adjusted properly when the meter reads 20. . Switch the selector switch to (-) leakage position and read the meter. . Switch the selector switch to (+) leakage position and read the meter. . Move the yellow lead to the next diode pair until each pair is tested. UA PWN AVALANCHE TEST: 1. After performing the leakage test the voltage can be varied with the Volts Adjustment until the leakage current rapidly increases, indicating that the diode is beginning to avalanche. 2. Then turn the selector switch back to DC Volts and read the meter forthe voltage level. | Avalanche Diode Tester IPM No. OT-0056 ‘INTRODUCTION Diodes being used in some of the new alternators are a special type. These special diodes are being used to help protect the electrical system from high voltage. These diodes are called transient suppressors or avalanche diodes. The diodes are also of the passivated die (chip) types; passivated means that the chip is sealed or protected and does not require a can or plastic moulded case. These diodes are, however, covered with silicon rubber in the alternator bridge assembly to prevent gross shorts caused by water and dirt. This tester is designed to test the normal rectification function of the diodes. In addition, the OT-0056 enables you to test the avalanche function and to determine the voltage at which the avalanche occurs. FUNCTION TEST Approximately 20 Volts AC peak is to be applied to the diodes during this test. The voltage is adjusted in the “AC Volts” position of the selector switch. The voltage is adjusted by turning the knob marked “Volts Adjustment” until the meter reads 20. LEAKAGE TEST Approximately 20 Volts DC is to be appled to, the diodes during this test. The voltage is adjusted in the “DC Volts” position of the selector switch. This is accomplished by turing the knob marked “Volts Adjustment”, until the meter reads 20. AVALANCHE VOLTAGE TEST . The meter is used to indicate a rapid increase of diode leakage. The DC voltage is increased until the leakage has been observed. The voltage is read by switching back to the “DC Volts” position of the selector switch. ——— OPERATION FUNCTION TEST 0 ONAKHAWNHE . Attach three test leads to the front of the tester. . Plug tester into 115 VAC outlet; grounded 3 wire outlets should be used. Turn Volts adjustment C.C.W. (to zero output). . Turn selector switch to AC Volts positon. Turn power switch to on. . Attach red lead to the positive heat sink. . Attach black test lead to the negative heat sink. . Attach the yellow test lead to the junction of one pair of positive and negative diodes. . Adjust the Volts Adjustment to read 20 on the meter (the two L.E.D. lights marked “Open” will be lit when the tester is on and the voltage tumed up. Disregard them except when testing with the selector switch in the “Function Test” position). 10. Switch to Function Test – all L.E.D. lights should be out – if any are lit then they are showing you the failure mode of the diodes., i.e. open or short. 11. Move-the yellow lead to the next diode pair until each pair is tested. / ! LEAKAGE TEST: L. Un BWhY AVALANCHE TEST: L 2 After performing the function test be sure the selector switch is turned to the DC Volts position. ~*” ” . The volts adjustment is adjusted properly when the meter reads 20. . Switch the selector switch to (-) leakage position and read the meter. . Switch the selector switch to (+) leakage position and read the meter. . Move the yellow lead to the next diode pair until each pair is tested. After performing the leakage test the voltage can be varied with the Volts Adjustment until the leakage current rapidly increases, indicating that the diode is beginning to avalanche. — turn the selector switch back to DC Volts and read the meter for the voltage | evel. |

File Type: pdf
File Size: 4 MB
Categories: manuals