FILE IN THE C) FOESTONMTEL SERVICE MANUAL Need SMALL MOTOR SECTION (Issued 3-16-78) These series type motors are designed for use in sirens. VOLTS 12 ROTATION CCWDE BRUSHES 2 POLES 4 BEARINGS Ball bearing at commutator end. LUBRICATION At overhaul, pack open ball bearing 1/4 to 1/2 full with a good ball bearing lubricant. SWITCH Separate BRUSH SPRING TENSION 26 to 30 ounces with new brushes. This tension is , measured with the scale hooked under the brush spring at the bend and the reading taken just as the spring leaves the brush. The pull of the spring scale is to be at right angles to the line of force exerted by the brush spring, TEST SPECIFICATIONS Stall Test 4.0 volts, 280 maximum amperes, 7.0 minimum Ft, Lbs. Free Running 10.0 volts, 40 maximum amperes, 11,000 minimum RPM. Unit MDS-4001 MDS-4002 MDS-4003, A, B MDS-4004 MDS~4005 TERMINAL POST GROUNDED BRUSH VIEWED FROM COMMUTATOR END