VOLTS 12 MEC FILE IN THE ©, Prestolite siRvick MANUAL LUBRICATION STARTING SWITCH BRUSH SPRING TENSION “| TRANSMISSION | COMMUTATOR END HEAD — | POLE SHOE ASSEMBLY | END PLAY _ | MAGNETIC SHIFT CLUTCHES SWITCH ACTION TEST ROTATION __32 to 48 ounces with new brushes. STARTING MOTOR SECTION (Issued 3-16-78) _CWDE _ BRUSHES . 4. POLES 4 – At overhaul, all bronze bearings should ‘be well lubricated with medium engine oil. Cover armature shaft at Drive End witb a film of lubricant before assembling drive. Solenoid. Mounted on motor. This tension is measured ° with the scale hooked under the brush screw and the reading – is taken just as the brush leaves the commutator. The pull of the spring scale is to be at right angles to the line of force exerted by the brush Spring. , Overrunning clutch Be sure felt oiling pad:is in the outer end of the commutator: ‘end bearing before assembling the commutator. end head on the motor. Install pole ‘shoes: so that the long tip is the trailing edge. __ Adjust. to,…005″ to 030″ Refer to Parts & Equipment List for thrust washer package, With plunger sealed, pinion pushed toward commutator end, and pinion stop pushed toward drive end bearing, a clearance of 1/64″ to 15/64″ between the pinion and pinion stop should be obtained. There are no provisions for adjusting this dimension. If dimension does not check tu these limits, the shift fork is excessively worn or the motor is improperly assembled. The pinion will be against the pinion stop when cranking. rs ray] 724 + spacer in place, the mag- bees netic switch should bottom and the switch contact should close under normal voltages. To test switch action on clutch type motors, slip a steel spacer (See Illus- tration for dimensions) over the armature shaft between the pinion and the pinion stop. With this Page 2 Sy Prestolite SERVICE MANUAL MEC contin PINION HOUSING SHUNT FIELD DRAW | . TEST SPECIFICATIONS – No Load Draw Stall Torque | — Bearing must be flush with the bearing bore on the inside of . ‘ the housing. , , (70°F .) 4.4’to’5.1 amperes at 10.0 volts. 10.0 volts, 48 maximum amperes, 5300 minimum RPM.. 4, 0 volts, 285 maximum amperes, 6.5 minimum Ft. Lbs. – _Unit «Pinion Position* MEC-6001 – °° 45/64″-55/64′” MEC-6002 41/64″-51/64″ MEC-6003 – . . 45/64″-55/64″ MEC-6101 41/64″-51/64″ . MEC-6102 . —s 41/64″”-51/64″” | . MEC-6103 . -. >. 41/64″-51/64″‘ – ’ TERMINAL . . ~ GROUNDED” INSULATED SRUSH INSULATED GROUNDED BRUSH VIEWED FROM COMMUTATOR END Figure 1 Printed in U S.A,