©, prestol te, _MGQ SERVICE Pump Motor Page 1 of 2 INFORMATION =—s____Revised_ayisag VOLTAGE 36 ROTATION CCWDE BRUSHES 4 POLES 4 VENTILATED See Tabulation FRAME DIAMETER 6-1/2″ LUBRICATION None required. Sealed ball bearings used at both , ends of motor. ~ BRUSH REPLACEMENT Replace brushes when they have worn to a length of 9/16″ or less. SPRING TENSION ; 30 to 36 ounces with new brushes. Measure with a spring scale hooked under the brush spring at the brush, Pull the scale on a line opposite the line of force exerted by the brush spring and take the reading just as the spring leaves the brush. ARMATURE TEST These armatures have equalizer connections on the commutator and cannot be tested on a growler for shorted windings. Test to light load specifica- tion, SHUNT FIELD RESISTANCE A resistance value of 15.20 to 16.80 chms (77°F /25°C) – measured between field coil (ring) terminals except for MGQ-4001 and 4002, measure between F-2 and field (ring) terminal. TEST SPECIFICATIONS (77°F /25°C) Terminal Maximum Torque Voltage Amperes RPM Ft. Lbs. No Load Test 36 10 2480 Min. 0 —~ Light Load Test 35.5 35 2060 to 2280 Y4 UNIT VENTILATED INTERNAL WIRING MGQ-4001 No Figure 1 MGQ-4001A Yes Figure 2 MGQ-4002 No Figure 1 MGQ-400 es igure MGQ-4002B No Figure 2 MGQ-4003 ,B No Figure 2 MGQ-4005 Yes Figure 2 —_ MGQ-4007 Yes Figure 2 Printed In U.S.A. L-600 SERVICE MANUAL => PUMP MOTOR SECTION MGQ Pump Motor Page 2 of 2 ____—-Revised 4/1/88 VIEWED FROM COMMUTATOR END FIG. 1 IN prestolite. : SERVICE INFORMATION SHUNT WINDING VIEWED FROM COMMUTATOR END FIG. 2