WX prestolite. MHW Starting Motors |. — SERVICE Page | of 1 INFORMATION Issued 3/16/78 VOLTAGE 24 ROTATION CWDE BRUSHES 8 POLES 4 DIAMETER 5-3/16″ LUBRICATION Lubricate armature shaft and fill cavity behind the shaft in the commutator end with Chevron BRB~? grease. BRUSH REPLACEMENT Replace brushes when they have worn to a length of —_ 3/8″ or less. SPRING TENSION 52 – 62 ounces with new brushes. Measure with a spring scale hooked under the brush spring at the brush. Pull the scale on a line opposite the line of force exerted by the brush spring and take the reading just as the spring leaves the brush. END PLAY Adjust to .005″ minimum with thrust washers at com- mutator end. See Parts & Equipment List for thrust washer package. — TEST SPECIFICATIONS (77°F /25°C) Terminal Maximum Torque Voltage Amperes RPM Ft. Lbs. No Load Test 10,0 110 6,500 – 0 – Stall Torque Test 2.0 740 -0O- 12.7 Unit MHW- 4001 TERMINAL POST —_ MHW- 4002 GROUNDED INSULATED BRUSH BRUSH “—. INSULATED BRUSH File in the STARTING MOTOR SECTION ann SERVICE MANUAL >> ee eee ae VIEWED FROM COMMUTATOR END