-_ Traction Motor SERVICE Page 1 of 1 INFORMATION Issued 3/16/78 ©, prestolite_ “5 VOLTAGE 36 ROTATION CCWDE BRUSHES 8 POLES 4 VENTILATED Yes FRAME DIAMETER 7-1/8″ LUBRICATION None required. Prelubricated and sealed ball bearings used at both ends of motor. FIELD RESISTANCE (77°F/25°C) 17.75 to 18.75 ohms measured between terminals A and §S. ARMATURE TEST These armatures have standard winding connections and can be tested on a growler using a metal strip or hacksaw blade to locate shorted windings. COMMU TATOR Minimum diameter 2.875″. Replace armature when commutator has worn to this dimension. BRUSH REPLACEMENT Replace brushes when cthey have worn to a length of 9/16″ or less. SPRING TENSION 30 to 36 ounces with new brushes. Measure with a spring scale hooked under the brush spring at the brush. Pull the scale on a line opposite the line of force exerted by the brush spring and take the reading just as the brush spring leaves the brush. TEST SPECIFICATIONS (77°F/25°C) Terminal Maximum Torque Voltage Amperes RPM Fe. Lbs. No Load Test 36 19 3250 min. -~ 0 ~ Light Load Test 36 175 1880/2100 17.5 UNIT MKH-4001,A4,B,5 ~ SERIES SHUNT MKH~- 4002,A,8B,5S WINDING . WINDING VIEWED FROM COMMUTATOR END CCWBE SHUNT WINDING WINDING File in the > oom TT Be Trartian Matar Sarrian