Printed in USA. S, prestolite «x SERVICE Pump Motor Page 1 of 1 INFORMATION Issued 2/16/82 VOLTAGE 72 ROTATION CCWDE BRUSHES 4 POLES a VENTILATED No FRAME DIAMETER 6-5/8″ LUBRICATION None required. Prelubricated and sealed ball bearings used at both ends of motor. SHUNT FIELD RESISTANCE 64 to 68 ohms measured between terminals “A” (779F/25°C) and “S”. COMMUTATOR Minimum diameter 2.875″. Replace armature when commutator has worn to this dimension. BRUSH REPLACEMENT Replace brushes when they have worn to a length of 9/16″ or less, SPRING TENSION 30 to 36 ounces with new brushes. Measure with a spring scale hooked under the brush spring at the brush. Pull the scale on a line opposite the line of force exerted by the brush spring and take the reading just as the spring leaves the brush. TEST SPECIFICATIONS (779F /259C) Terminal] Maximum Torque Voltage Amperes RPM Ft. Lbs. No Load Test 36 4 1350 – Q0- Light Load Test 74.8 13 1850 to 2050 2 Unit MKR- 4001 MKR- 4002 MKR-4003 MKR~4004 MKR- 4005 MKR- 4006 VIEWED FROM COMMUTATOR END File in the . Pump Motor Section