Printed In U.S.A, IN VOLTAGE 12 VENTILATED No BEARINGS LUBRICATION BRUSH REPLACEMENT SPRING TENSION POLE SHOE INSTALLATION END PLAY TEST SPECIFICATIONS No Load Test Stall Torque Test File in the L-600 SERVICE MANUAL restate. SERVICE INFORMATION ROTATION See Tabulation MMY_ Pump Motor Page 1 of 2? Issued 4/1/88 BRUSHES 4 POLES 4 FRAME DIAMETER 4-1/2″ Absorbent bronze bearings used at commutator end. Prelubricated and sealed bal] bearing used at drive end but not supplied with drive end head. Soak absorbent bronze bearings and felt oiling pad with SAE 20 oil. Allow excess oj] to drain out before assembling end head on motor. Ball bearings are prelubricated and sealed and require no additional lubrication. The brushes must be replaced when they have worn to a length off 1/4″ or less. 32 to 40 ounces with new brushes. Measure with a spring scale hooked under the brush spring at the brush, Pull the scale on a line opposite the line of force exerted by the brush spring and take the reading just as the spring leaves the brush, When installing field coils, install the pole shoes so that the longer tip is pointing in the same direction as armature rotation. Adjust to .005″ to .030″ with thrust washers on the commutator end of the armature shaft. Refer to Parts & Equipment List for thrust washer package. (77°F /26°C) Terminal Maximum Torque Voltage Amperes RPM Ft. Lbs. 10,0 55 6500 Min, 0) 2 330 0 8.0 [> PUMP MOTOR SECTION MMY = IN prestolite. Pump Motor Page 2 of 2 SERVICE Issued 4/1/88 INFORMATION INTERNAL UNIT ROTATION WIRING MMY-4001,A CCWDE Fig. 1 MMY-4002,5 CWDE Fig. 2 FIG. 1 GROUNDED INSULATED BRUSH BRUSH VIEWED FROM COMMUTATOR END FIG. 2