CONVERTER CIRCUIT The NEW ENGINEERING Power Converter converts 220 volt AC power into 12 volt (or 12 and 24 volt) full-wave rectified (pulsating) DC power. ‘Uhts 1s accomplished using a heavy duty (3K VA) 24 Volt center tapped transformer and large power rectifiers ‘The rectifiers are rated at 275 amps and 400 PIV and are mounted on fan-cooled aluminun heat sinks. 12 volt power 1s attained using a standard 2-rectifier, center-tap circuit and works as follows …. (refer to drawing). … As the “B” output of the transfonmer secondary coil reachcs maximum negative voltage, the center tap “C” is 12 volts positive (with relation to the “B” out put) The “A” output 1s now 24 volts positive in relation to the “B” output. Ifa load is connected across the mam NEG and 12V POS terminal posts, current will flow from the center tap to the 12V POS output post and through the load. The current then flows into the NEG heat sink and through the No. 1 rectifier (on the NEG heat sink) which 1s connected to the “B” transformer output. No current flows through any other rectifiers at this tyme. As the cycle reverses and the “A” output reaches max negative, the center tap becomes 12V POS in relation to the “A” output. Current again flows from the center tap, out the POS post and through the load. As the current enters the NEG heat sink, it now flows through the No.2 rectifier back to the transformer. Thus, in the 12 volt operating mode, the two NEG rectifiers (No.l & No.2) take turns in pulsing full-wave power into the load. In the 24 volt operating mode, the NEG and the 24V POS posts, now form a four rectifier full-wave bridge used to rectify the 24V voltage across “A” and”B”. The center tap “C” is not used. The 24 volt circuit works as follows… As the “A” output of the transformer reaches max. positive voltage, current flows through the No.4 rectifier to the 24V POS heat sink. Current flows through the load to the NEG heat sink and then through the No.1 rectifier back to transformer tap “B” As the cycle reverses and “B” becoines positive, current flows through rectifier No.3 through the load through rect. No. | and back to transformer “A”. Thus, both 12V and 24V modes provide full-wave rectified DC power to the load. In addition, the 12V and 24V power outlets can be used SIMULTANEOUSLY so long as the maximum power rating for the Converter is not exceeded Power Converter TROUBLE SHOOTING The New Engrg. Power Converter is a rugged but simple power supply designed to give years of service. Should a problem arisc, this trouble shooting guide should be followed to locate it. A bricf description of the circuit will sct the stage for trouble shooting Power (220 VAC) comes into the unit through the plug and Jine cord. The center prong on the power plug ts connected to the green wire and is grounded to the case of the Converter. The black and white leads, which carry the 220 volts, both pass through a two-pole circuit breaker which also serves as the on-off switch. Power leaving the circuit breaker then goes to the input of the transformer as well as the fan and the pilot light. Jn some modct Converters, the fan is controlled by a thermostat which turns the fan on only when needed. The output side of the transformer consists of three heavy leads. The center Icad goes directly to the POSitive 12 volt output post of the Converter. ‘(he two outer leads each pass through a large rectifier. Both rectifiers are mounted on an alinninun heat sink which, in turn, is mounted on (or connected to) the NEGative output post. Experience shows that the transformer is the component least likely to fail This is duc to its conservative design and the protection afforded by the circuit breaker. More Itkely to fait are the rectifiers. ly this occurs, the failure is almost always a short. This short puts an overtoad an the transformer causing the breaker to trip. Attempts to re-set the breaker wul be unsuccessful To test for this type of rectifter faulure, sumply remove the power plug trom the 220V socket. Set the breaker to its up position and plug the power cord in. Ifthe breaker trips, you can be 90% sure that onc (01 more) of the rectifiers has shorted. If the breaker will not stay in the up position even when the power Itnc is disconnected, you have a bad breaker. To make a positive test on the rectifiers, follow thesc steps. 1. REMOVE THE 220V POWER PLUG FROM TILE SOCKET! Never work on open electrical equipment while it is plugged in! 220 volts will deliver a LETHAL SHOCK! 2. Remove the six hex-head screws fromm the front panel of the Converter. This will enable you to move the pancl far enough away from the main case to work inside the Converter 3. Locate the two large rectifters (usuatly located directly behind the Negative post). The rectilter pigtails are covered with insulating tape and/or sleeving. Locate the bulge under the insulation about 6 inches from the rectifier body. This is the connecting bolt which joins the recttfier to the transformer output lead. 4. Cut away the insulation on either of the two rectifier leads aud remove the bolt thus breaking the connection between pigtail and transformer. Now both rectifiers can be tested. 5. Use an ohm incter or a diode tester to determine the condition of both rectifiers IY the machine 1s over three years old, you should consider replacing both rectifiers even uf only one is bad. When replacing rectifiers, it is eastest to remove the aluminuin heat sink from the output post stud.

File Type: pdf
File Size: 3 MB
Categories: manuals